Written Date 2011-03-24 Examination Writer Do Geun Chang Subject ZA-P20 RF TEST MANUAL Doc No Approval Bang Jun Wan Doc Class Test Manual Version 1.0 Doc Manager ZigBee Adaptor(ZA-P20) Subject: Test Manual KQF-0705-1(0) LG Electronics Inc.
011-03-24 RF Test Manual Ver 1.0 . 1 Operation Method 1. Connect DUT and Power Supply, and Turn on PC. 1) Connect Sample’ s RS232C Port and PC’ s RS232C Port with RS232 serial Cable. 2) DUT’ s Power and GND Line at Power Supply(+12V), and Turn on Switch. 2. DUT and PC serial communication setting 2.1 Hyper Terminal setting BIT/Sec(B) : 115200 DATA BIT(D) : 8 PARITY(P) : NONE STOP BIT(S) : 1 FLOW CONTROL : NONE Primary Value KQF-0705-1(0) Change Value LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 3. TEST COMMAND 3.1 settxpowmode l p – POWER Mode Setting Command 1) Operation Method > Command Setting Mode 2) Setting Mode I p 0 0: Normal-mode, PA-internal 0 1: Normal-mode, PA-External 1 0: Boost-mode, PA-internal 1 1: Boost-mode, PA-External 3) Execution Scene 3.2 settxpower p – Output Power Setting Command 1) Operation Method > Command Setting Mode 2) Power Range : +8 ~ -32 3) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 3.3 setchannel c – Channel setting Command 1) Operation Method > Command Setting Mode (Range: 0x0B ~ 0x1A ) > Channel 0x0B -> Change the 0x0B channel, Channel value must be hexadecimal.
2011-03-24 RF Test Manual Ver 1.0 3.3 txtone – Un-modulated Singnal Command 1) Operation Method > Command Setting Mode > txtone Transmitting Carrier frequency. Press 'e'xit to stop 2) txtone (Unmodulated Singnal) TEST A. settxpowmode 0 1 B. settxpower 0 C. setchannel 0x0B (see the Channel Table) D. txtone Command Execution 3) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 3.4 txstream – Modulated signal’ s Maximum rate transmission mode 1) Operation Method > Command Setting Mode > txstream 'e'nd... 2) txstream(Modulated Signal) TEST A. settxpowmode 0 1 B. settxpower 0 C. setchannel 0x0B (see the Channel Table) D. txstream Command Execution 3) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 3.5 rx – rx mode 1) Operation Method > Command Setting Mode > rx Entering RX mode, press c to reset, press e to exit 2) rx TEST A. settxpowmode 0 1 B. settxpower 0 C. setchannel 0x0B (see the Channel Table) D. rx Command Execution 3) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 4. RF TEST Method 4.1 un-modulated CW Signal Test 1) Command input for un-modulated signal test(txtone) A. settxpowmode 0 1 B. settxpower 0 C. setchannel 0x0B (see the Channel Table) D. txtone Command Execution 2) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 4.2 Modulated Signal Test 1) Command input for TEST (txstream) A. settxpowmode 0 1 B. settxpower 0 C. setchannel 0x0B (see the Channel Table) D. txstream Command Execution 2) Execution Scene KQF-0705-1(0) LG Electronics Inc.
2011-03-24 RF Test Manual Ver 1.0 4.3 rx Mode Setting 1) Command input for receive TEST A. settxpowmode 0 1 B. settxpower 0 C. setchannel D. rx 0x0B (see the Channel Table) Command execution 2) Execution Scene This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.