ESPAÑOL Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm). ITALIANO Models: SE/S3 Series Type: ART COOL Mirror Type ENGLISH LG FRANÇAIS DEUTSCH IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
Artcool Deluxe Type Indoor Unit Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS Safety Precautions.................3 Write the model and serial numbers here: Model # Prior to Operation ..................8 Serial # Product Introduction..............9 You can find them on a label on the side of each unit. Operating Instructions.........10 Date Purchased Maintenance and Service ....12 ■ Staple your receipt to this page in the event you need to prove date of purchase or to issue warranty.
Safety Precautions Safety Precautions WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING ■ Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
Safety Precautions Do not modify or extend the power cable. • There is risk of fire or electric shock. For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Do not install, remove, or re-install the unit by yourself (customer). • There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. • It may cause injury, accident, or damage to the product.
Safety Precautions Do not store or use flammable gas or combustibles near the product. Do not use the product in a tightly closed space for a long time. • It may cause There is risk of fire, failure of the product, or electric shock. • There is risk of fire or failure of product. • Oxygen deficiency could occur. Gasolin When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. If strange sounds, or small or smoke comes from product.
Safety Precautions When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. • There is risk of product damage or failure, or unintended operation. Take care to ensure that nobody could step on or fall onto the outdoor unit. • This could result in personal injury and product damage. CAUTION ■ Installation Always check for gas (refrigerant) leakage after installation or repair of product. • Low refrigerant levels may cause failure of product.
Safety Precautions Do not block the inlet or outlet of air flow. • There is risk of fire, electric shock, or damage to the plastic parts of the product. Do not touch the metal parts of the product when removing the air filter. They are very sharp! • There is risk of personal injury. x Wa Thinner Do not step on or put anyting on the product. (outdoor units) • There is risk of personal injury and failure of product. Do not drink the water drained from the product.
Prior to operation Prior to Operation Preparing for operation 1. Contact an installation specialist for installation. 2. Use a dedicated circuit. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time. 2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices. 3.
Product Introduction Product Introduction Here is a brief introduction of the indoor units. Please see the information specific to your indoor unit type.
Operating Instructions Operating Instructions Name and Function of Remote Controller (Optional) AUTO SWING OPERATION SET TEMP FAN SPEED Room Temp AUTO Heater Preheat JET Defrost Humidify SLo Filter Out door ZONE 1 2 3 4 HI MED LO 1 2ndF Timer SUB FUNCTION Time Operation unit No Func Program set On Off Set no.
Operating Instructions Wireless Remote Controller(Optional) of handling the Remote Controller • Aim at the signal receptor on the wired remote controller so as to operate. • The remote control signal can be received at a distance of up to about 7m. • Be sure that there are no obstructions between the remote controller and the signal receptor. • Do not drop or throw the remote controller.
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system. Never use any of the followings: • Water hotter than 40°C. Could cause deformation and/or discoloration. • Volatile substances. Could damage the surfaces of the air conditioner. Pow d er G a s o li n e Air Filters The air filters behind the front panel / grill should be checked and cleaned once in every 2 weeks or more often if necessary.
Maintenance and Service When the air conditioner is not going to be used for a long time. When the air conditioner is to be used again. Operate the air conditioner at the following settings for 2 to 3 hours. • Type of operation: Fan operation mode. • This will dry out the internal mechanisms. Turn off the breaker. Clean the air filter and install it in the indoor unit. (Refer to page 12 for cleaning it.) Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Maintenance and Service Before you call for service... ? Troubleshooting Tips! Save time and money! Check the following points before requesting repairs or service.... If the malfunction persist, please contact your dealer. The air conditioner does not operate. The room has a peculiar odor. It seems that condensation is leaking from the air conditioner. Air conditioner does not operate for about 3 minutes when restart.