ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ∂§§∏¡πÃÕ PORTUGUÊS NEDERLANDS OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED POLSKI www.lg.
Air Conditioner Owner’s Manual TABLE OF CONTENTS A. Safety Precautions ..............................3 FOR YOUR RECORDS B. Electrical Safety...................................6 Temporary Use of an Adapter ...............6 Temporary Use of an Extension Cord ...6 Symbols used in this Manual.................6 Write the model and serial numbers here: C. Product Introduction...........................7 Dealer's Name D. Operating Instructions........................8 How to insert the Batteries ...........
Safety Precautions Safety Precautions This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. Always use a power plug and socket with a ground terminal. • There is a risk of electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
Safety Precautions Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after installation or svc and then tear away and throw away the plastic packaging bags. Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely.
Safety Precautions Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. • There is risk of damage or loss of property. • There is risk of personal injury. Do not insert hands or other objects through the air inlet or outlet while the product is operating. • There are sharp and moving parts that could cause personal injury. Do not tilt the unit when removing or uninstalling it.
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Product Introduction ENGLISH Artcool Mirror Type Display panel LCD indicators Air inlet Air filter Plasma filter Air discharge Front panel Signal receiver ON/OFF button On/Off : Lights up during the system operation, and auto restart setting. Sleep mode : Lights up during sleep mode auto operation. Plasma : The function illustrates its dynamic mode by using a multiple lighting system. Timer : Lights up during timer operation.
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1. Always use/replace both batteries of same type. 2. If the system is not to be used for a long time, remove the batteries to save their working life. 3.
Operating Instructions Wireless Remote Controller The controls will look like the following. OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTION BUTTON Used to select fan speed in six steps low, medium-low, medium, medium-high, high and natural wind. HORIZONTAL VANE CONTROL BUTTON Used to set the desired vertical airflow direction.
Operating Instructions The controls will look like the following. Signal transmitter SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation. JET COOL/JET HEAT BUTTON Used to start or stop the speed cooling and heating. The Jet Cool/Jet Heat operates fan in super high speed.
Operating Instructions Operation Mode 1 Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep. 2 Open the cover of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Auto Changeover Operation (Single Air Conditioner) This operation is basically heating or cooling function of the air conditioner. But during this operation the controller changes the operation mode automatically to keep the temperature within ±2°C with respect to the setting temperature. MODE Auto Operation(Multi Air Conditioner) In this operation, mode is automatically set by the logic based on the current temperature and connected indoor unit.
Operating Instructions Air Circulation Operation MODE ENGLISH This operation circulates the air without cooling or heating. It can be activated by pressing the OPERATION MODE SELECTION BUTTON. Once the air circulation is activated you can select the fan speed by pressing the INDOOR FAN SPEED SELECTION BUTTON. Auto Clean Operation ❏ During Auto Clean Operation, moistures left in indoor units after cooling operation or healthy dehumidification operation can be removed.
Operating Instructions Energy-Saving Cooling Mode Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting desired temperature automatically. 1. Press the ON/OFF BUTTON to start the unit. 2. Open the cover of the remote controller. Select cooling operation. 3. Press the ENERGY-SAVING COOLING MODE BUTTON. 4.
Operating Instructions Timer Setting Description Press the Timer button once to set on the Reserved 'On' (Press the Timer button twice to set the Reserved 'Off') 2 Press the Time Setting buttons until the desired time is set. - The order of a.m. and p.m. -> hour ->minute is repeated whenever you press the < > button. - By pressing the button, you can set the desired time.
Operating Instructions Horizontal Vane Control The Horizontal Vane can be adjusted by using the remote controller. 1. Press the ON/OFF BUTTON to start the unit. 2. Press the vertical airflow direction button. The horizontal vane will swing up & down automatically. To Stop the vane at a desired angle, press the vertical airflow direction button again. Vertical Louver Control The Vertical Louvers can be adjusted by using the remote controller. 1. Press the ON/OFF BUTTON to start the unit. 2.
Operating Instructions Forced operation Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop the operation, re-press the button. ENGLISH Power Power button button Cooling Model Operating mode Indoor FAN Speed Setting Temperature Cooling High 22°C Room Temp. ≥ 24°C Cooling High 22°C Heat pump Model 21°C ≤ Room Temp. < 24°C Healthy Dehumidification High 23°C Room Temp.
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these • Water hotter than 40°C. It may cause deformation and discoloration. • Volatile substances. They may damage the surface of the air conditioner.
Maintenance and Service Outdoor Unit NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room. Keep blinds or curtains closed. This is not good for the health and wastes electricity. Make sure that the doors and windows are shut thight. Avoid opening doors and windows as much as possible to keep the cool air in the room. Do not let direct sunshine enter the room when the air conditioner is in operation.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Air conditioner does not start Air conditioner does not cool as it should Possible Causes What To Do ■ The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. ■ The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. ■ Power failure.