Use and Care Manual

Table Of Contents
24 INSTALLATION
buildup and free of restrictions allows clothes to
dry faster and reduces energy use.
The appliance should be cool before starting this
test. If the appliance was warmed up during
installation, run the Air Dry cycle for a few
minutes to reduce the interior temperature.
Activating the Installation Test
1 Remove any packing materials or other items
from inside the drum and close the door.
Do not load anything in the drum for this
test, as it may affect the accuracy of the
results.
2 Press the Power button and IMMEDIATELY
press and hold the Temp. and Dry Level
buttons.
The cycle LEDs will flicker if the activation is
successful.
3 Press the Start/Pause button.
The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
4 Check the display for results.
During the test cycle, monitor the Flow
Sense
TM
display on the control panel. If the
Flow Sense
TM
LED has not turned on when
the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense
TM
LED will turn
on. Other problems may also be shown with
error codes. See the chart on the next page
for error code details and solutions.
•The Flow Sense
TM
LED indicates that the
exhaust system is severely restricted. Have
the system checked immediately, as
performance will be poor.
5 End of cycle.
At the end of the test cycle, a chime will
sound and the appliance will shut off
automatically after a short delay.
After entering the Install mode, illuminating the
Normal cycle means the heating state.
After entering the Install mode, illuminating the
Heavy Duty cycle means the cooling state.
The option LED is gradually illuminated, which
means that the oulet temperature is increasing.
Check the Duct Condition
If the Flow Sense
TM
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
Do not interrupt the test cycle, as this could
result in inaccurate results.
Even if the Flow Sense indicator does not light up
during the test cycle, some restrictions may still
be present in the exhaust system. Refer to the
Venting the Dryer section of this manual for
complete exhaust system and venting
requirements.
Error Codes
Check the error code before you call for service.
When an error occurs, various LEDs will light up
and a chime will sound.
LED
light
Possible Cause & Solution
Low or
Medium
Temperature sensor failure.
Turn off the appliance and call for
service.
Energy
Saver
Humidity sensor failure.
Turn off the appliance and call for
service.