The AC cable connector of the last AC module should be sealed for weather proof function. End caps are initially paired
with connectors. Installers can use suitable end cap for different type of connector at the last AC module.
To prevent property damage or danger to human life by fire or explosion, do not connect any
consumable device between AC module and the circuit breaker.
To prevent the danger of the electric shock, make sure to turn off the circuit breaker.
Attach the AC Cable to the PV racks using the cable ties. Let the AC cables float way from the ground
surface or the roof.
All of AC cable connectors must be installed underneath the module, out of rain and sun. Do not leave
AC cable connectors in an environment of long-term exposure to direct sunlight or rain.
AC cables from the junction box to the distribution panel should be protected by a conduit.
39
Copyright © 2017 LG Electronics.
All Rights Reserved.
※ End caps are Initially paired with connectors.
Sealing the last AC module connector
※ Use a proper end cap for the
last AC module connector.
※ End caps are Initially paired with connectors.
Use unlocking tool for getting an end cap from a connector. Refer to 3-8 Coupling AC cable
Connectors.
※ Use a proper end cap for the
last AC module connector.