User guide

*Unit: mm
T : T -BAR
M : M-BAR
Existing lamp LG FLAT 53W
of planting 17 trees
Comparison of CO
2
emissions
(unit: kgCO
2
)
34% -
70%
53W/60W
User Manual
The meanings of the signs displayed on the product and user manual are as follows:
This sign means use caution for dangerous items and operations. For parts with this sign,
user must read the manual carefully and follow instructions in order to avoid risks.
This sign is for displaying risks involving electric shock under certain conditions.
LG’s test standards
If used 12 hours each day for a year
Conversion constant 0.573 kgCO
2
/Kwh, 3.86kgCO
2
/tree)
This function is provided as an optional part.
conditions of use.
Replacing existing lighting devices with the LED FLAT LIGHT can reduce energy costs by 30% or more.
Product is mercury-free, presenting no harm to the environment or human body. Its annual CO
2
emissions have been dramatically reduced, making it an environment-friendly product.
Low carbon emissions allows environmentally-friendly lighting
Existing light LED FLAT LIGHT
It provides the lowest and best glare level in the industry by producing pleasant, healthy, and
natural light without the use of a louver.
Natural light prevents glare
Safety PrecautionsLED FLAT LIGHT
Advantages
LED FLAT LIGHT
Dimming control utilizing an illumination intensity sensor reduces electricity usage, thereby
providing approximately 70% energy reduction.
Dimming control provides additional energy reduction costs
If used for 12 hours a day, the product can be used for 10 or more years without replacement.
Thus, maintenance costs are low, making it an economically sound option.
Long life expectancy provides low maintenance cost
Product is heavy. Use a trolley when
transporting the product.
Dropping the product may cause
product damage and malfunction.
Do not install in areas that have risks
of ooding.
Risk of electric shock.
Do not install on un-leveled ceilings.
• Risk of product falling, which may lead
to product damage and injury to the
user.
Install a circuit breaker.
Risk of re and electric shock.
Perform grounding work.
Risk of electric shock.
Please read the
Safety Precautions prior to use for your safety.
This manual is intended to prevent product damage and protect the user’s safety.
Place the manual at a place where it can be easily located by all potential users.
WARNING
WARNING
Violation of warnings may lead to serious injury or death.
CAUTION
Violation of precautions may lead to light injury or product damage.
1. T-BAR
• Make sure to turn off the main power switch of the installation space before connection.
• Connect so that the colors of the 3 power cables match.
(LIVE: BROWN, NEUTRAL: BLUE, P.E.: GREEN/YELLOW)
• When this luminaire is connected to branch circuit, installation engineer must use the connector
that is ame retardance of UL-94 V0 or higher.
Installation
Electricity 80W
Electricity 53W
Existing lamp LED LED (Dimming control)
Electricity 24W
Reduction in electric energy usage
Light control application provides energy reduction
Dimming control system
Turn power o before installation.
• Risk of electric shock.
Do not store in a humid area.
• Risk of product malfunctioning.
Do not install near potential
sources of re or inammable
objects, such as paper or cloth.
• Risk of product malfunctioning and
accidents.
Must x the product properly
on the ceiling.
• Risk of product dropping and causing
injury to the user.
Do not disassemble or arbitrarily
remodel the product. Do not use for
underwater lighting purposes.
(Underwater landscape, searchlight,
shing, events, etc.)
• Risk of re and electric shocks.
Do not randomly connect the power
polarities.
• Risk of product damage and accidents.
Must use woodscrews provided by
LG Electronics during installation.
• Risk of product falling and injury to
user.
Do not use the product if impurities
are present in the product or if the
product is submerged.
• Risk of accidents such as electric shock
and product damage.
Must have at least two or more
people working during installation.
• Risk of product dropping and causing
injury to the user.
If the lamp turns o by itself, do not
disassemble the product. Contact
your local LGE sales representative
for repair.
• Risk of electric shock and product
malfunctioning.
Do not stare directly at the lamp
when turned on.
• Strong light may cause visual
impairment.
Do not use for purposes other than
lighting.
(Heating food, drying clothes, etc.)
• Risk of re.
Do not use if the product has been
dropped or exposed to shock.
• Risk of product malfunctioning.
Do not install where it may be
exposed to direct sunlight, humidity,
or dust.
Do not expose the product to water
when cleaning it.
• Risk of re and electric shock.
Never disassemble the product.
• Risk of accidents such as electric shock
and product damage.
Do not clean the product with
inammable substances such as
alcohol, benzene, and acetone that
may alter the surface.
Drill and prepare the ceiling
so the hole is smaller than the
product.
1
Connect the 3 product cables
to the interior wiring of the
building. For wire connectors,
use standardized products.
2
Interior wiring
of the building
Product’s
power cables
NEUTRAL
LIVE
P.E.
NEUTRAL
LIVE
P.E.
Wire connectors
Rotate the connected
product by 20 degrees.
Then insert it into the T-bar
insertion space.
• Make sure that all 4 sides of
the product match the T-bar.
3
Place the horizontal product
into the T-bar.
4
Ensure the inserted product
is horizontal.
5
Once installation is complete,
turn on the power switch to
check it is operating properly.
• After the installation is
complete, remove the
protective sheet.
6
2. Product Size
< 600 x 600 Type > < 300 x 1200 Type >
Top Cover
Bottom Cover
Converter
Do not install product in places
exposed to dampness.
Risk of re.
Use with proper rated voltage.
Risk of re and product damage.
Electric work must be performed by a
certied technician according to the
installation manual.
Benzene
Alcohol
WARNING WARNING
CAUTION
Inadequate power capacity and faulty electric
work may lead to re or electric shock.
T: 596/620
M: 620
T: 1256
M: 1270
T: 296
M: 310
94
T: 596/620
M: 620
T: 94/96
M: 96
MFL67182201

Summary of content (2 pages)