Owners manual
23
INSTALLATION
ENGLISH
NOTE
A self piercing saddle type water valve 
should not be used. 
NOTE
The hookup line cannot be white, plastic 
tubing. Licensed plumbers must use 
only copper tubing (NDA tubing #49595 
or #49599) or Cross Link Polyethylene 
(PEX) tubing.
If your existing copper water line has a  
y
flared fitting at the end, you will need 
an adapter (available at plumbing supply 
stores) to connect the water line to the 
refrigerator OR you 
can cut off the flared 
fitting with a tube 
cutter and then use a 
compression fitting.
Shutoff valve 
y
 to connect to the cold 
water line. The shutoff valve should 
have a water inlet with a minimum 
inside diameter of 5/32 in. at the point of 
connection to the COLD WATER LINE. 
Saddle-type shutoff valves are included 
in many water 
supply kits. Before 
purchasing, make 
sure a saddle-type 
valve complies with 
your local plumbing codes.
Water Line Installation Instructions
Install the shutoff valve on the nearest 
frequently used drinking water line.
1
SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the 
pressure on the line.
2
CHOOSE THE VALVE LOCATION
Choose a location for 
the valve that is easily 
accessible. It is best to 
connect into the side of a 
vertical water pipe. When 
it is necessary to connect 
into a horizontal water 
pipe, make the connection to the top or 
side, rather than at the bottom, to avoid 
drawing off any sediment from the water 
pipe.
3
DRILL THE HOLE FOR THE VALVE 
Drill a ¼ in. hole in 
the water pipe using 
a sharp bit. Remove 
any burrs resulting 
from drilling the hole 
in the pipe. Be careful 
not to allow water 
to drain into the drill. Failure to drill a ¼ in. 
hole may result in reduced ice production 
or smaller cubes.
 WARNING
When using any electrical device 
(such as a power drill) during 
installation, be sure the device is 
battery powered, double insulated 
or grounded in a manner that will 
prevent the hazard of electric shock.