Use and Care Manual

41 Product Data
YA Chassis
PTAC
6RWU0-03A
Heating Capacity
UYH073ALE21(LP073HD2B)
Indoor Air
Temperature
Outdoor Air Temperature : DB°F
32 42.8 50 59
DB°F TC PI TC PI TC PI TC PI
60.8 5.89 0.45 6.85 0.49 7.42 0.51 8.19 0.55
64.4 5.71 0.47 6.64 0.50 7.18 0.53 7.93 0.57
68.0 5.54 0.48 6.40 0.52 6.97 0.55 7.69 0.59
71.6 5.34 0.50 6.21 0.54 6.72 0.57 7.41 0.61
75.2 5.15 0.51 5.99 0.55 6.49 0.58 7.16 0.62
Indoor Air
Temperature
Outdoor Air Temperature : DB°F
32 42.8 50 59
DB°F TC PI TC PI TC PI TC PI
60.8 7.55 0.58 8.78 0.63 9.50 0.66 10.49 0.71
64.4 7.31 0.60 8.50 0.65 9.20 0.68 10.16 0.73
68.0 7.09 0.62 8.20 0.67 8.93 0.71 9.86 0.76
71.6 6.84 0.64 7.95 0.69 8.61 0.73 9.50 0.78
75.2 6.60 0.66 7.68 0.71 8.31 0.75 9.17 0.80
Indoor Air
Temperature
Outdoor Air Temperature : DB°F
32 42.8 50 59
DB°F TC PI TC PI TC PI TC PI
60.8 9.94 0.79 11.56 0.85 12.52 0.89 13.82 0.96
64.4 9.63 0.81 11.20 0.88 12.12 0.92 13.38 0.99
68.0 9.34 0.84 10.80 0.91 11.76 0.95 12.98 1.02
71.6 9.01 0.87 10.47 0.93 11.34 0.98 12.51 1.05
75.2 8.70 0.89 10.11 0.96 10.95 1.01 12.08 1.09
UYH093ALE31(LP093HD3B)
Symbol Notes
DB : Dry Bulb Temperature [°F] 1. All capacities are net, evaporator fan motor heat is deducted.
WB : Wet Bulb Temperature [°F] 2. Indicates nominal capacity.
TC : Total Capacity [kBtu/h]
PI : Power Input [kW]
(Comp.+ indoor fan motor + outdoor fan motor)
UYH123ALE31(LP123HD3B)