Measurement Guide

36"
(91.4 cm)
29.8"
(75.7 cm)
24"
(60.9 cm)
Cabinet
Cabinet
opening
A
Acceptable
electrical
outlet area
3" (7.6 cm)
24"
(60.9 cm)
3" (7.6 cm)
25"
(63.5 cm)
Normal counter
top depth
36"
(91.4 cm)
Counter
top height
4"
(10 cm)
9"
(23 cm)
9"
(23 cm)
4"
(10 cm)
Wall
Center
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
2.5"
(6.3 cm)
A
= 30" (76.2 cm)
30"
(76.2 cm)
*30" (76.2 cm)
Minimum
**15"
(38.1 cm)
36"
(91.4 cm)
MINIMUM DIMENSIONS
* 30” (76.2 cm) minimum
clearance between the top of
the cooking surface and the
bottom of an unprotected wood
or metal cabinet; or
24” (60.9 cm) minimum when
bottom of wood or metal
cabinet is protected by not
less than 1/4”(6.4 cm) ame
retardant millboard covered
with not less than no. 28 MSG
sheet steel, 0.015” (0.381 mm)
stainless steel, 0.024”
(0.610 mm) aluminum or
0.020” (0.508mm) copper.
** 15” (38.1 cm) minimum
between countertop and
adjacent cabinet bottom.
DIMENSIONS AND CLEARANCES
This appliance must be installed and
grounded on a branch circuit by a qualied
technician in accordance with the National
Electrical code ANSI/NFPA NO. 70 - latest
edition.
All wiring should conform to Local and NEC
codes. This range requires a single-phase, 3
wire, A.C 120/208 V or 120/240 V 60 Hz
electrical system. Use only a 3-conductor or
a 4-conductor UL - listed range cord with
closed-loop terminals, open-end spade lugs
with upturned ends or similar termination.
Do not install the power cord without a
strain relief.
A range cord rated at 40 amps with
120/240 minimum volt range is required.
If a 50 amp range cord is used, it should
be marked for use with 13/8" diameter
connection openings. This appliance may
be connected by means of a conduit or
power cord. If a conduit is being used, check
the Owners Manual for 3 wire conduit
connections or 4 wire conduit connections.
! Warning
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of
slack in the line so that the range can be
moved if servicing is ever necessary.
• The power supply cord and plug should
not be modied. If it will not t the
outlet, have a proper outlet Installed by
a qualied electrician.
• Using an extension cord to connect the
power is prohibited. Connect the power
cord and plug directly.
• Electrical ground is required on this
appliance.
• Make sure that the power cord is not
pinched by the range or heavy objects.
Failure to do so can result in serious
burns or electrical shock.
Specified power-supply-cord kit rating
Range rating, watts
Specified
rating of
power
supply-
cord kit,
amperes
Diameter (inches)
of Range
connection
Opening
120/240
volts
3-wire
120/208
volts
3-wire
Power
cord
Conduit
8,750 -
16,500
16,501 -
22,500
7,801 -
12,500
12,501 -
18,500
40 or 50A
50
1
3
/
8
"
1
3
/
4
"
1
1
/
8
"
1
3
/
8
"
4 Wire
receptacle
(14-50R)
3 Wire
receptacle
(10-50R)
ELECTRICAL REQUIREMENTS
36"
(91.4 cm)
29.8"
(75.7 cm)
24"
(60.9 cm)
Cabinet
Cabinet
opening
A
Acceptable
electrical
outlet area
3" (7.6 cm)
24"
(60.9 cm)
3" (7.6 cm)
25"
(63.5 cm)
Normal counter
top depth
36"
(91.4 cm)
Counter
top height
4"
(10 cm)
9"
(23 cm)
9"
(23 cm)
4"
(10 cm)
Wall
Center
15" (38 cm)
11" (28 cm)
2.5" (6.3 cm)
6"
(15.2 cm)
5"
(13 cm)
6"
(15.2 cm)
2.5"
(6.3 cm)
A
= 30" (76.2 cm)
30"
(76.2 cm)
*30" (76.2 cm)
Minimum
**15"
(38.1 cm)
36"
(91.4 cm)
LSE4611*
Quick Install &
Clearances
For full installation directions/clearances please refer to
the corresponding User Manual and Installation Guide.
Please read the installation instructions rst after purchasing
this product or transporting it to another location.
DIMENSIONS/CLEARANCES/WEIGHT
Shipping Weight 188 lbs.
Product Weight 164 lbs.
Cabinet Width (in) 30"
Overall Depth (in) - including handle 28-15/16"
Overall Height (in) - including backguard 37-59/64”
Overall Width (in) 29-15/16"
Oven Interior Dimensions
(in) (W x H x D) 24-13/16" x 21-5/16" x 19-3/4"
Height to Cooking Surface (in) 36"
Storage Drawer Dimensions
(in) (W x H x D) 22-3/16" x 4-1/2" x 16-3/8"
Carton Dimensions
(in) (W x H x D) 31-31/32" x 51" x 30-17/32"
POWER/RATINGS
Amp Rating at 208V 40A
Amp Rating at 240V 40A
KW Rating at 208V 9.5kW
KW Rating at 240V 12.6kW
LG Brand_Slide In Ranges Fin_1.indd 2 8/21/17 4:23 PM