Owners manual

Controlling Multiple Products
RS-232C
A10
Transmission / Receiving Protocol
19. Time (Command 1: f, Command 2: a)
Set the current time.
Transmission Acknowledgement
[f][a][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr] [a][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data1: ffh (read)
00h to 06h (write of Time Day) (not use)
(*transmit by Hexadecimal code)
Data2: ffh : read Time Hours
00h to 17h : write of Time Hours
(*transmit by Hexadecimal code)
Data3: ffh : read Time Minutes
00h to 3bh : write of Time Minutes
(*transmit by Hexadecimal code)
* The day of week cannot be set even if Data 1 is entered.
20. On Time (On/Off Timer) (Command 1: f, Command 2: d)
Set On Timer.
Transmission Acknowledgement
[f][d][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr] [d][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data1 : f1h : read index of On Time
e1h : write of On Time off
80h : write of On Time on
(*transmit by Hexadecimal code)
Data 2 : ffh : read of On Time Hours
00h to 17h : write of On Time Hours
(*transmit by Hexadecimal code)
Data 3 : ffh : read of On Time Minutes
00h to 3bh : write of On Time Minutes
(*transmit by Hexadecimal code)
21. Off Time (On/Off Timer) (Command 1: f, Command 2: e)
Set Off Timer.
Transmission Acknowledgement
[f][e][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr] [e][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data 1 : f1h : read index of Off Time
e1h : write of Off Time off
80h : write of Off Time on
(*transmit by Hexadecimal code)
Data 2 : ffh : read of Off Time Hours
00h to 17h : write of Off Time Hours
(*transmit by Hexadecimal code)
Data 3 : ffh : read of Off Time Minutes
00h to 3bh : write of Off Time Minutes
(*transmit by Hexadecimal code)