Owners manual
Controlling Multiple Products
RS-232C
A12
Transmission / Receiving Protocol
25. Tile Mode (Command 1: d, Command 2: d)
► Change a Tile Mode.
Transmission Acknowledgement
Data (Hex)
[d][d][ ][Set ID][ ][Data][Cr] [d][ ][Set ID][ ][OK/NG][Data][x]
26. Tile mode check (Command 1: i, Command 2: a)
► Check the tile mode.
Transmission Acknowledgement
The data is always FF (in Hexa)
[i][a][ ][Set ID][ ][Data][Cr] [a][ ][Set ID][ ][OK/NG][Data][x]
27. H Size (Command 1: d, Command 2: g)
► To set the Horizontal position.
Transmission Acknowledgement
Data Min : 00H to Max : 14H (*transmit by Hexadecimal code)
If the H tile is set to 1, it does not work.
[d][g][ ][Set ID][ ][Data][Cr] [g][ ][Set ID][ ][OK/NG][Data][x]
28. V Size (Command 1: d, Command 2: h)
► To set the Vertical position.
Transmission Acknowledgement
Data Min : 00H to Max : 14H (*transmit by Hexadecimal code)
If the V tile is set to 1, it does not work.
[d][h][ ][Set ID][ ][Data][Cr] [h][ ][Set ID][ ][OK/NG][Data][x]
Data IR Remote Key
00, 11 Tile mode is off.
12 1 x 2 mode
13 1 x 3 mode
… …
FF 15 x 15 mode
ex) Data 13 : Indicates that the H Tile is 1 and the V Tile is 3.
Except for 00, a value 0X or X0 cannot be used.