Controlling Multiple Products
RS-232C
A13
Transmission / Receiving Protocol
29. Tile ID (Command 1: d, Command 2: i)
Assigns the tile ID.
Transmission Acknowledgement
Data Min : 1H to Max : E1 (*transmit by Hexadecimal code)
[d][i][ ][Set ID][ ][Data][Cr] [i][ ][Set ID][ ][OK/NG][Data][x]
30. Master (Command 1: g, Command 2: b)
Assigns the master for the multi function.
Transmission Acknowledgement
Data 0 : Master Off, 1 : Master On
* The Master function receives the monitor status in RS232C mode.
When multiple sets are connected, the Master function must be enabled only for one set.
[g][b][ ][Set ID][ ][Data][Cr] [b][ ][Set ID][ ][OK/NG][Data][x]
31. Fan Control (Command 1: g, Command 2: c)
► Controls the fan.
Transmission Acknowledgement
Data 0 : Natural Off
[g][c][ ][Set ID][ ][Data][Cr] [c][ ][Set ID][ ][OK/NG][Data][x]
Data Fan Control Mode
00 Off
01 On
02 Auto
32. Fan Active Temp (Command 1: g, Command 2: d)
► Sets the operation temperature of the fan.
Transmission Acknowledgement
Data Min : 14H to Max : 64H (*transmit by Hexadecimal code)
[g][d][ ][Set ID][ ][Data][Cr] [d][ ][Set ID][ ][OK/NG][Data][x]