Owners manual
Controlling Multiple Products
RS-232C
A15
Transmission / Receiving Protocol
37. Software Version (Command 1: f, Command 2: z)
► Checks the software version.
Transmission Acknowledgement
The data is always FF (in Hex) To read the software version.
[f][z][ ][Set ID][ ][Data][Cr]
[z][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data1 6 : 06
Data2 0 : 00
Data3 0 : 00
38. Panel Time (Command 1: d, Command 2: l)
► Checks how long the panel of the monitor is used.
Transmission Acknowledgement
The data is always FF (in Hex)
Data1,2:Day (Data are 2byte long in Hex ASCII format)
[d][l][ ][Set ID][ ][Data][Cr] [l][ ][Set ID][ ][OK/NG][Data1][Data2][x]
39. Sub Brightness (Command 1: h, Command 2: a)
► Sets the brightness of the factory menu.
Transmission Acknowledgement
Data Min : 3B to Max : BA (*transmit by Hexadecimal code)
[h][a][ ][Set ID][ ][Data][Cr] [a][ ][Set ID][ ][OK/NG][Data][x]
40. Sub Contrast (Command 1: h, Command 2: b)
► Sets the contrast of the factory menu.
Transmission Acknowledgement
Data Min : 40 to Max : BF (*transmit by Hexadecimal code)
[h][b][ ][Set ID][ ][Data][Cr] [b][ ][Set ID][ ][OK/NG][Data][x]
ex) DID IN HD EU V6.00 100416