Owners manual
Controlling Multiple Products
RS-232C
A17A17
Transmission / Receiving Protocol
45. Green Gain (Command 1: h, Command 2: g)
► Sets the green offset of the factory menu.
Transmission Acknowledgement
Data Min : 40 to Max : BF (*transmit by Hexadecimal code)
[h][g][ ][Set ID][ ][Data][Cr] [g][ ][Set ID][ ][OK/NG][Data][x]
46. Blue Gain (Command 1: h, Command 2: h)
► Sets the blue offset of the factory menu.
Transmission Acknowledgement
Data Min : 40 to Max : BF (*transmit by Hexadecimal code)
[h][h][ ][Set ID][ ][Data][Cr] [h][ ][Set ID][ ][OK/NG][Data][x]
47. Backlight (Command 1: h, Command 2: i)
► Sets the backlight of the factory menu.
Transmission Acknowledgement
Data Min 0, 19, 32, 4B, 64, 7D, 96, AF, C8, E1, FA (*transmit by Hexadecimal code)
48. Input List (Command 1: k, Command 2: b)
► To select input source for the Set.
Transmission Acknowledgement
[h][i][ ][Set ID][ ][Data][Cr]
[k][b][ ][Set ID][ ][Data][Cr]
[i][ ][Set ID][ ][OK/NG][Data][x]
[b][ ][Set ID][ ][OK/NG][Data][x]
Data(Hexa) Input List
7 RGB
9 HDMI/DVI
2 AV
4 Component