User's Manual

User Manual
PAGE :
DOCUMENT No. :
REG. DATE : 2020.04.09
MODEL NAME : ETWFAEWC01
REV. NO : v1.0
©2020 LGIT. All rights reserved.
4 / 7
REV. DATE : 2020.04.09
WC40154
Parameter Min Typ Max Unit
Operating Temperature
1)
-20 - +70
Operating Humidity (40) - - 85 %
Supply Voltage
1)
10.8 12 13.2 Vdc
The Test for electrical specification shall be performed under the following condition
Otherwise this following conditions, not guaranteed this performance.
5. Operating Test Conditions
Temperature
25 ± 2
Humidity
65 ± 5%
Input power(VDD) Supply Voltage
+12V
+12V ± 10%
6. Standard Test Conditions
6-1. Ambient condition
6-2. Power supply voltages
Human Body Model (HBM) Min. Max. Unit
Contact -
±6
kV
Air -
±12
6-4. ESD Information
Note 1 : IEC 61000-4-2 (150pF, 330R)
1)
It can be operated from 8V to 16V, but this voltage range shouldn’t be guaranteed