DIMENSIONS / CLEARANCES
A Width 29 7/8"
B Height 37 1/4"
C Depth (Includes Door Handle) 29 3/8"
D Height (Excludes Vent Trim) 36"
E Depth (Includes only the product body that is loaded
into the cabinet.Excludes door, drawer, and handles)
24 3/4"
F Depth (Excludes Door Handle) 26 7/8"
G Depth when drawer is fully opened 36 1/16"
H Depth when door is fully opened 48 5/8"
CLEARANCES
1 Minimum 30"
2 Minimum clearance to left/right wall 5"
3 Maximum depth for cabinets above countertops 13"
4 Front edge of the range side panel forward
from cabinet
1/4"
5 To cabinets below cooktop and at the range back 0"
CONNECTING GAS
Providing Adequate Gas Supply
•
Your range is designed to operate at a pressure of 5” of water column on natural
gas or 10” of water column on LP.
•
Make sure you are supplying your range with the type of gas for which it is
congured.
•
This range is convertible for use on natural or LP gas. When using this range on
LP gas, conversion must be made by a qualied LP installer before attempting to
operate the range.
•
For proper operation, the pressure of natural gas supplied to the regulator must
be between 5” and 13” of water column.
•
For LP gas, the pressure supplied to the regulator must be between 10” and 13”
of water column. When checking for correct operation of the regulator, the inlet
pressure must be at least 1” more than the operating (manifold) pressure as
given above.
•
The pressure regulator located at the inlet of the range must remain in the supply
line regardless of which type of gas is being used.
•
A exible metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 5/8” and a maximum length of 5 feet. In Canada,
exible connectors must be single wall metal connectors less than 6 feet in
length
▲
! WARNING
•
Isolate the range from the gas supply system by closing its individual shut-off
valve during any pressure testing of the gas supply system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
•
The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psi (3.5 kPa).
Electrical Requirements
•
This appliance must be installed and grounded on a branch circuit by a qualied
technician in accordance with the National Electrical code ANSI/NFPA NO. 70 -
latest edition.
•
All wiring should conform to Local and NEC codes. This range requires a single-
phase, 3 wire, AC 120/208 V or 120/240 V 60 Hz electrical system. Use only a
3-conductor or a 4-conductor UL - listed range cord with closed-loop terminals,
open-end spade lugs with upturned ends or similar termination. Do not install the
power cord without a strain relief.
•
A range cord rated at 40 amps with 120/240 minimum volt range is required. If
a 50 amp range cord is used, it should be marked for use with 13/8” diameter
connection openings. This appliance may be connected by means of a conduit or
power cord. If a conduit is being used, refer to “3-Wire Connection: Conduit”
or “4-Wire Connection: Conduit” sections in the Owner’s Manual.
▲
! WARNING
•
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be
moved if servicing is ever necessary.
•
The power supply cord and plug should not be modied. If it will not t the outlet,
have a proper outlet installed by a qualied electrician.
•
Using an extension cord to connect the power is prohibited. Connect the power
cord and plug directly.
•
Electrical ground is required on this appliance.
•
Make sure that the power cord is not pinched bythe range or heavy objects.
Failure to do so can result in serious burns or electrical shock.
CONNECTING ELECTRICITY
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
4
Cabinet
3
Counter top height
2
Normal counter top depth
1
Acceptable electrical outlet area
6
Center
5
Wall
A (Cabinet opening)
= 30" (76.2 cm)
For U.S.A
= 30" (76.2 cm) ~
= 31" (78.7 cm)
For CANADA