Owner's Manual

Table Of Contents
28 INSTALLATION
chart on the next page for error code details
and solutions.
•If the Flow Sense(
W) display indicates that
the exhaust system is severely restricted,
have the system checked immediately, as
performance will be poor.
5 End of cycle.
At the end of the test cycle, ENd will display.
The test cycle will end and the appliance will
shut off automatically after a short delay.
Check the Duct Condition
If the Flow Sense(W) indicator is turned on, check
the exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
Do not interrupt the test cycle, as this could
result in inaccurate results.
Even if no bars are displayed during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
Error Codes
Check the error code before you call for service.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed transition duct
Error
Code
Possible Cause & Solution
tE1 or
tEz
Temperature sensor failure.
Turn off the appliance and call for
service.
Hs
Humidity sensor failure.
Turn off the appliance and call for
service.
Ps, PF,
or
NP
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
QAs
Gas supply or service turned off. (Gas
Model only.)
Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Error
Code
Possible Cause & Solution