External Control Device Setup ; RS-232C
External Control Device Setup ; RS-232C
Reference
Reference
*
: Refer to 02. Input Selecton page 67
Baud rate : 9600 bps (UART)
Data length : 8 bits
Parity : None
* Use a crossed (reverse) cable.
Stop bit : 1 bit
Communication code : ASCII code
Communication Parameters
Communication Parameters
Transmission
*
[Command 1]: First command. (m or k)
*
[Command 2]: Second command.
*
[Set ID]: You can adjust the set ID to choose desired monitor
ID number in Special menu. Adjustment range is 1
~ 99. When selecting Set ID 0, every connected
TV set is controlled. Set ID is indicated as decimal
(1~99) on menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
*
[DATA]: To transmit command data.
Transmit FFdata to read status of command.
*
[Cr]: Carriage Return
ASCII code 0x0D
*
[ ]: ASCII code space (0x20)
[Command1][Command2][ ][Set ID][ ][Data][Cr]
T
T
ransmission / Receiving Protocol
ransmission / Receiving Protocol
OK Acknowledgement
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
[Command2][ ][Set ID][ ][OK][Data][x]
Error Acknowledgement
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving abnormal data from non-viable
functions or communication errors.
[Command2][ ][Set ID][ ][NG][Data][x]
01. Power k a 0 ~ 1
02. Input Select k b
03. Aspect Ratio k c 0 ~ 6
04. Screen Mute k d 0 ~ 1
05. Volume Mute k e 0 ~ 1
06. Volume Control k f 0 ~ 64
07. Contrast k g 0 ~ 64
08. Brightness k h 0 ~ 64
09. Colour k i 0 ~ 64
10. Tint k j 0 ~ 64
11. Sharpness k k 0 ~ 64
12. OSD Select k l 0 ~ 1
13.
Key Lock
k m 0 ~ 1
14. Balance k t 0 ~ 64
15. Tune Command m a 0 ~ 63
16. Skip programme m b 0~1
17. Key m c Key Code
COMMAND
1
COMMAND
2
DATA
(Hexa)
Command Reference List
Command Reference List
*
Set ID
Set ID
- Use this function to specify a monitor ID number.
- Refer to Real Data Mapping 1. See page 67.
1. Press the MENU button and then use
DD
/
EE
button to select the
Setup menu.
2. Press the
GG
button and then use
DD
/
EE
button to select Set ID.
3. Press the
GG
button and then use
FF
/
GG
button to adjust Set ID to
choose the desired monitor ID number. The adjustment range of
Set ID is 1 ~ 99.
4. Press the OK button to save.
Setup
Language
Input
Child lock
Set ID
DE F G
OK MENU
1