Operation Manual
45
EXTERNAL CONTROL DEVICE SETUP
ENGENGLISH
*
Realdatamapping
00 :
Step 0
A : Step 10 (Set ID 10)
F : Step 15 (Set ID 15)
10 : Step 16 (Set ID 16)
64 : Step 100
6E : Step 110
73 : Step 115
74 : Step 116
CF : Step 199
FE : Step 254
FF : Step 255
23. Input select (Command: x b)
(Main Picture Input)
► To select input source for main picture.
Data Structure
MSB LSB
Transmission [x][b][ ][Set ID][ ][Data][Cr]
External Input Input Number
0 0 0 0 0 0 0 0
Ack [b][ ][Set ID][ ][OK/NG][Data][x]
External Input Data
0 0 0 0 DTV
0 0 0 1 Analogue
0 0 1 0 AV
0 1 0 0 Component
0 1 1 0 RGB
0 1 1 1
HDMI
1 0 0 0
1 0 0 1
1 0 1 0
Input Number Data
0 0 0 0 Input1
0 0 0 1 Input2
0 0 1 0 Input3
0 0 1 1 Input4
Ack [v][ ][Set ID][ ][OK][Data01][Data02][x][v][ ][NG][Data01][x]
24. 3D(Command: x t) (only 3D models)
(Depending on model)
► To change 3D mode for TV.
Transmission
[x][t][ ][Set ID][ ][Data 01][ ][Data 02]
Data Structure
Data 01 00 : 3D On
01 : 3D Off
02 : 3D to 2D
03 : 2D to 3D
Data 02 00 : Top and Bottom
01 : Side by Side
02 : Checker Board
03 : Frame Sequential
Data 03 00 : Right to Left
01 : Left to Right
Data 04 3D Effect(3D Depth): Min : 00 - Max : 14
(*transmit by Hexadecimal code)
* If data1 is 00(3D On), data4 has no meaning.
* If data1 is 01(3D off) or 02(3D to 2D), data2, data3 and data4
have no meaning.
* If data1 is 03(2D to 3D), data2 and data3 have no meaning.
X : don’t care
25. Extended 3D(Command: x v) (only 3D models)
(Depending on model)
► To change 3D option for TV.
Data 01 : 3D option
00 : 3D Picture Correction
01 : 3D Depth (2D to 3D only)
02 : 3D Viewpoint
03 : 3D Picture Size (Plasma TV only)
04 : 3D Picture Blance (Plasma TV only)
05 : 3D Optimization (Active type (LCD TV) only)
Data 02 It has own range for each 3D option determined
by Data 01.
1) When Data 01 is 00
00 : Right to Left
01 : Left to Right
2) When Data 01 is 01, 02
Data Min: 0 - Max: 14 (*transmit by Hexadecimal code)
Data value range(0 - 20) converts Viewpoint range (-10 - +10)
automatically (Depending on model)
3) When Data01 is 03
00 : Just Scan
01 : 16:9
4) When Data01 is 04
00 : Off
01 : On
5) When Data01 is 05
Data Min: 0 - Max: 02(*transmit by Hexadecimal code)
*Refer to 'Real data mapping'.
[ ][Data 03][ ][Data 04][Cr]
Ack [t][ ][Set ID][ ][OK][Data01][Data02][Data03][Data04][x]
[t][ ][Set ID][ ][NG][Data00][x]
Transmission [x][v][ ][Set ID][ ][Data 00][ ][Data 01][Cr]
Data 1 Data 2 Data 3 Data 4
00 O O X
01 X X X
02 X X X
03 X X O