Connect the RS-232C input jack to an external control device (such as a computer or an A/V control
system) and control the set’s functions externally.
RS-232C input socket
1. Connect the serial port of the control device to the RS-232C jack on the set.
2. RS-232C connection cables are not supplied with the set.
3. The set’s remote control handset and side panel controls (except main power) will not be function-
al if the set is controlled by a PC computer or other external device.
D-Sub 9-pin male
Set ID
Use this function to specify a monitor ID number.
Refer to ‘Real Data Mapping’. See page 40.
1. Press the MENU button and then use the
DD
/
EE
button to select
the SPECIAL menu.
2. Press the
GG
button and then use
DD
/
EE
button to select Set ID.
3. Press the
GG
button and then use
FF
/
GG
button to adjust Set ID
to choose the desired monitor ID number.
Note : The adjustment range of Set ID is 0 ~ 99.
Communication Parameters
• Baud rate : 9600 bps (UART) • Data length : 8 bits
• Parity : None • Stop bit : 1 bit
• Communication code : ASCII code
* Use a crossed (reverse) cable.
No. Pin name
1 No connection
2 RXD (Receive data)
3 TXD (Transmit data)
4 DTR (DTE side ready)
5 GND
6 DSR (DCE side ready)
7 RTS (Ready to send)
8 CTS (Clear to send)
9 No Connection