Owner’s Manual
Table Of Contents
- OWNER’S MANUAL
- USER GUIDE
- INSTALLATION MANUAL
- ACCESSING INSTALLATION MENU
- INSTALLATION MENU
- LG Digital Signage Setup menu
- Signage Mode Operation
- Power On Status
- Key Operation
- IR Operation / Local Key Operation
- Limited Mode
- Input Source Change
- Menu Display
- OSD Display
- Power On Default (Input Source, A/V Setting, Aspect Ratio)
- Input Source
- A/V Setting
- Aspect Ratio
- Wake On LAN
- DPM
- Digital Audio Input
- Speaker
- Power On Delay
- Pivot Mode
- OSD Portrait Mode (Off, 90, 270)
- Intelligent Auto
- Master/Slave Mode
- Time Sync Clock
- Sync Mode
- DPM Wakeup Control
- Still Image Detecting
- PM Mode
- Factory Reset
- OPS/PC Power Control
- Interface Selection
- Check Screen
- Factory Reset VS Initial Setting
- Signage Mode Operation
- USB Cloning
- Password Change
- Set ID Setup
- Configuration Setup
- Lock Mode
- External Speaker / Audio out
- Fail Over
- ISM Method
- Easy Brightness Control
- SuperSign Server Setup
- Holiday Schedule
- No Signal Image
- Crestron
- Digital Signage Media Player
- LG Digital Signage Setup menu
ENGLISH
40
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command1] Identifies the factory setting and the user setting modes.
* [Command2] Controls monitors.
* [Set ID] Used for selecting a set you want to control. A Set ID can be assigned to each set from 1 to
255 (from 01H to FFH), or from 1 to 1,000 (from 001H to 3e8H) in certain models, under
OPTION in the OSD menu. Selecting '00H' or '000H' for Set ID allows the simultaneous control
of all connected monitors. (It may not be supported depending on the model.)
* [Data] Transmits command data.
Data count may increase depending on the command.
* [Cr] Carriage Return. Corresponds to '0x0D' in ASCII code.
* [ ] White Space. Corresponds to '0x20' in ASCII code.
Acknowledgement
[Command2][ ][Set ID][ ][OK/NG][Data][x]
* The Product transmits an ACK (acknowledgement) based on this format when receiving normal data. At this time,
if the data is FF, it indicates the present status data. If the data is in data write mode, it returns the data of the PC
computer.
* If a command is sent with Set ID ‘00’ (=0x00) or ‘000 (=0x000)’, the data is reflected to all monitor sets and they do
send any acknowledgement (ACK).
* If the data value ‘FF’ is sent in control mode via RS-232C, the current setting value of a function can be checked (only
for some functions).