19
Customer Computer RS-232C configurations
3-Wire Configurations (Not standard)
1
6
5
9
PC TV
RXD
2 2
TXD
TXD
3 1
RXD
GND
5 3
GND
OR
RXD
3 2
TXD
TXD
2 1
RXD
GND
5 3
GND
D-Sub 9 Phone
RS-232C
(Serial port)
Set ID
For Set ID number, see Real Data Mapping.
1.  Press SETTINGS to access the main menus.
2.  Press the navigation buttons to scroll to (*General About this TV or OPTION) and press OK.
3.  Press the navigation buttons to scroll to SET ID and press OK.
4.  Scroll left or right to select a set ID number and select CLOSE. The adjustment range is 1-99.
5.  When you are finished, press EXIT.
* (Depending upon model)
Communication Parameters
•  Baud rate: 9600 bps (UART)
•  Data length: 8 bits
•  Parity: None
•  Stop bit: 1 bit
•  Communication code: ASCII code
•  Use a crossed (reverse) cable.