88.  [Dual Screen Off] (Command: s n, 92)
Turn Dual Screen On or Off.
Transmission
(s)(n)( )(Set ID)( )(9)(2)( )(Data)(Cr)
Data  00: MainScreen – On / SubScreen – On
  01: MainScreen – Off / SubScreen – On
  02: MainScreen – On / SubScreen – Off
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(9)(2)(Data)(x)
*  This feature may not be supported in certain models.
89.  [Fan control] (Command: d o)
Sets the fan mode.
Transmission
(d)(o)( )(Set ID)( )(Data)(Cr)
Data  00:   Auto
  01:   On
  02:   Manual
  03:   Off
Acknowledgement
(o)( )(Set ID)( )(OK/NG)(Data)(x)
*  This may not be supported on some models.
90.  [Fan Failure Check] (Command: d w)
Checks for fan failures.
Transmission
(d)(w)( )(Set ID)( )(Data)(Cr)
Data  FF: Read status
Acknowledgement
(w)( )(Set ID)( )(OK/NG)(Data1)(Data2)(x)
Data1  00: One or more fans are faulty.
  01: All fans are normal.
  02: The model has no fan.
Data2  00: No fan is faulty (all fans are normal).
  01: 1 fan is faulty.
  02: 2 fans are faulty.
  03: 3 fans are faulty.
  04: 4 fans are faulty.
  05: 5 fans are faulty.
  06: 6 fans are faulty.
  07: 7 fans are faulty.
  08: 8 fans are faulty.
  09: 9 fans are faulty.
  0A: 10 fans are faulty.
 …
  N: N down
91.  [Luminance Value Read] (Command: m u)
Reads luminance value.
Transmission
(m)(u)( )(Set ID)( )(FF)(Cr)
Acknowledgement
(u)()(SetID)()(OK/NG)(Data1)(Data2)(Data3)
(Data4)(Data5)(Data6)(Data7)(x)
Data1  00–64: The Backlight PWM value (0 to 100)
Data2  00–ff: The upper 1-byte of the value measured by the 
CA210.
Data3  00–ff: The lower 1-byte of the value measured by the 
CA210.
CA210 measurement: 0000 to ffff in hexadecimal and 0 to 65535 
in decimal.
Data4  00–ff: The upper 1-byte of the value measured by BLU 1 
sensor.
Data5  00–ff: The lower 1-byte of the value measured by BLU 1 
sensor.
Data6  00–ff: The upper 1-byte of the value measured by BLU 2 
sensor.
Data7  00–ff: The lower 1-byte of the value measured by BLU 2 
sensor.
BLU measurement: 0000 to ffff in hexadecimal and 0 to 65535 
in decimal.
*  During final assembly, a CA210 measurement is entered through the 
calibration procedure. The default value, before calibration, is 0.
*  This may not be supported on some models.
92.  [BLU Maintenance] (Command: m t)
Selects whether to turn on/off BLU Maintenance.
Transmission
(m)(t)( )(Set ID)( )(Data)(Cr)
Data  00: BLU Maintenance Off
  01: BLU Maintenance On
Acknowledgement
(t)( )(Set ID)( )(OK/NG)(Data)(x)
*  This may not be supported on some models.