Installation Manual

Installation Manual 25
How to Set E.S.P?
ENGLISH
M3 (28k~54k)
(Unit: CMM(CFM))
Note: 1. The above table shows the correlation between the air rates and E.S.P.
2. Make sure to check and adjust E.S.P (external static pressure) value after the
installation of the product. Otherwise, there is a risk of weak cooling/heating and
condensed water discharge/drop.
Setting
Value
Static Pressure (mmAq(in wg))
4(0.16) 6(0.24) 8(0.31) 10(0.39) 12(0.47) 14(0.55) 16(0.59) 18(0.71) 20(0.79)
70 25.2(891)
75 30.4(1 074) 21.4(756)
80 35.0(1 235) 27.1(959) 18.5(654)
85 39.8(1 404) 35.4(1 250) 24.6(869)
90 44.3(1 562) 40.1(1 416) 31.5(1 111) 22.7(800)
95 49.3(1 741) 44.8(1 581) 36.8(1 300) 28.8(1 017) 21.4(754)
100 53.0(1 872) 49.4(1 744) 44.6(1 574) 35.4(1 251) 27.7(978)
105 57.2(2 020) 54.1(1 910) 49.2(1 737) 43.0(1 518) 35.0(1 234) 26.5(935)
110 58.8(2 076) 53.9(1 903) 47.9(1 691) 42.4(1 497) 33.8(1 193) 24.3(858) 14.8(522)
115 58.6(2 069) 52.9(1 867) 47.8(1 687) 42.5(1 500) 31.4(1 108) 20.3(717) 18.3(646)
120 57.8(2 040) 53.1(1 874) 48.2(1 701) 39.2(1 384) 30.2(1 066) 24.6(868)
125 54.2(1 913) 49.4(1 744) 43.1(1 520) 36.7(1 296) 33.1(1 168)
130 54.6(1 927) 52.7(1 860) 48.6(1 714) 44.4(1 567) 39.6(1 398)
135 50.2(1 772) 45.2(1 596)