Installation Manual

8 INSTALLATION
Installing the Cooktop
Installing the Cooktop Unit
1 Locate the electrical outlet and gas shut-off
valve in the cabinet beneath the cooktop. The
access cap on the gas regulator must face the
front of the cabinet and be easily accessible.
Never reuse old flexible connectors.
Install a manual shut-off valve
b in the gas
line in an easily accessible location outside the
cooktop. Be sure you know how and where to
shut off the gas supply to the cooktop. Install
the electrical outlet 12˝ a below the
countertop.
2 Carefully lower the cooktop into the
countertop cutout, making sure not to trap
any wires.
3 Remove the retainer brackets from the
literature package.
- Dimension/Clearance 30" Cooktop 36" Cooktop
A Width of upper plate 30" (760 mm) 36" (915 mm)
B Depth of upper plate 21" (533 mm)
C Height of cooktop base 3 3/4" (95 mm)
D Width of cooktop base 28 1/4" (717 mm) 33 5/8" (854 mm)
E Depth of cooktop base 19 3/8" (492 mm)
F Width of cutout 28 1/2" (724 mm) 33 7/8" (860 mm)
G Depth of cutout 19 5/8" (498 mm)
H Distance from cutout to side wall on the left of unit. /
Distance from cutout to side wall on the right of the
unit.
211 13/16" (300 mm)
I Distance from front edge of cutout to front edge of
countertop
21 5/8" (41 mm)
J Distance between cutout and the wall behind the
cooktop
22 3/4" (69 mm)
K Width of unprotected overhead cabinets
230" (760 mm) 236" (915 mm)
L Depth of unprotected overhead cabinets
113" (330 mm)
M Clearance from countertop to unprotected overhead
surface
230" (760 mm)
N Clearance from countertop to nearest cabinet on
either side of unit
218" (457 mm)