26 INSTALLATION
2 Press and hold the Signal and Temp. buttons
and then press the Power button.
On models with a glass touch control panel,
press the Power button then IMMEDIATELY
press and hold the Temp. and Wrinkle
Care buttons.
This button sequence activates the
installation test. The code
1N will display if
the activation is successful.
3 Press the Start/Pause button.
The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
4 Check the display for results.
During the test cycle, monitor the Flow
Sense
TM
display on the control panel. If the
Flow Sense
TM
LED has not turned on when
the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense
TM
LED will turn
on. Other problems may also be shown with
error codes. See the chart on the next page
for error code details and solutions.
•The Flow Sense
TM
LED indicates that the
exhaust system is severely restricted. Have
the system checked immediately, as
performance will be poor.
5 End of cycle.
At the end of the test cycle,
O will display.
The test cycle will end and the appliance will
shut off automatically after a short delay.
Check the Duct Condition
If the Flow Sense
TM
LED is turned on, check the
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
When the appliance is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
Do not interrupt the test cycle, as this could
result in inaccurate results.
Even if no bars are displayed during the test
cycle, some restrictions may still be present in
the exhaust system. Refer to the Venting the
Dryer section of this manual for complete
exhaust system and venting requirements.
Error Codes
Check the error code before you call for service.
Error
Code
Possible Cause & Solution
tE1 or
tEz
Temperature snesor failure.
Turn off the appliance and call for
service.
Hs
Humidity sensor failure.
Turn off the appliance and call for
service.
Ps, PF,
or
NP
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.