User manual

C
HAPTER
8
| Spanning Tree Algorithm
Configuring Interface Settings for STA
– 115 –
ES-2000 Series
path cost recommended by the IEEE 8021w standard exceeds 65,535,
the default is set to 65,535.
Admin Link Type – The link type attached to this interface.
Point-to-Point – A connection to exactly one other bridge.
Shared – A connection to two or more bridges.
Auto – The switch automatically determines if the interface is
attached to a point-to-point link or to shared media. (This is the
default setting.)
Admin Edge Port – Refer toAdmin Edge Status for all ports” at the
beginning of this section.
Migration – If at any time the switch detects STP BPDUs, including
Configuration or Topology Change Notification BPDUs, it will
automatically set the selected interface to forced STP-compatible
mode. However, you can also use the Protocol Migration button to
manually re-check the appropriate BPDU format (RSTP or STP-
compatible) to send on the selected interfaces. (Default: Disabled)
WEB INTERFACE
To configure interface settings for STA:
1. Click Spanning Tree, STA.
2. Select Configure Interface from the Step list.
3. Select Configure from the Action list.
4. Modify any of the required attributes.
5. Click Apply.
Table 9: Recommended STA Path Cost Range
Port Type IEEE 802.1D-1998 IEEE 802.1w-2001
Ethernet 50-600 200,000-20,000,000
Fast Ethernet 10-60 20,000-2,000,000
Gigabit Ethernet 3-10 2,000-200,000
Table 10: Default STA Path Costs
Port Type Short Path Cost
(IEEE 802.1D-1998)
Long Path Cost
(802.1D-2004)
Ethernet 65,535 1,000,000
Fast Ethernet 65,535 100,000
Gigabit Ethernet 10,000 10,000