User manual

C
HAPTER
5
| Interface Configuration
Saving Power
– 92 –
ES-2000 Series
analyzes cable length to determine whether or not it can reduce the
signal amplitude used on a particular link.
N
OTE
:
Power savings can only be implemented on Gigabit Ethernet ports
when using twisted-pair cabling. Power-savings mode on a active link only
works when connection speed is 1 Gbps, and line length is less than 60
meters.
PARAMETERS
These parameters are displayed:
Port – Power saving mode only applies to the Gigabit Ethernet ports
using copper media.
Power Saving Status – Adjusts the power provided to ports based on
the length of the cable used to connect to other devices. Only sufficient
power is used to maintain connection requirements. (Default: Enabled
on Gigabit Ethernet RJ-45 ports)
WEB INTERFACE
To e na ble p ow er s avin gs:
1. Click Interface, Green Ethernet.
2. Mark the Enabled check box for a port.
3. Click Apply.
Figure 45: Enabling Power Savings