Installation Guide
13
PLANNING THE INSTALLATION
ENGLISH
Ductwork Design Tips
Wherever possible, reduce the number of transitions 
and turns to as few sharp angles as possible. Two 
staggered 45° angles are better than one 90°.
Keep turns as far away from the hood exhaust as 
possible, and allow as much space between bends 
as possible.
For best performance, use round ducts instead of 
rectangular, especially when elbows are required.
If multiple elbows are used, try to keep a minimum of 
24" of straight duct between them.
Avoid “S” or “back to back” use of adjacent elbows.
In regions where the weather gets extremely cold, 
use thermal breaks, such as a short section of non-
metallic duct, to avoid indoor heat loss. Locate the 
break as close as possible to the outside pass-
through point.
Do not use flexible metal duct.
Do not use ductwork that is smaller in cross-sectional 
area than the recommended types above.
Power Supply
WARNING
•
The information in this manual should be 
followed exactly. Failure to do so could result 
in fire or electrical shock, causing property 
damage, personal injury or death.
•
All electrical work must by performed by 
qualified electrician or person with similar 
technical knowledge and background.
•
For personal safety, remove house fuse or open 
circuit breaker before beginning installation. Do 
not use extension cord or adapter plug with this 
appliance.
•
Follow national electrical codes or 
prevailing local codes and ordinances.
Electrical Supply
This appliance requires a 120V 60Hz electrical 
supply, and must be connected to an individual, 
properly grounded branch circuit, protected by a 15 or 
20 ampere circuit breaker or time delay fuse. Wiring 
must be 2 wire w/ ground. Please also refer to the 
Electrical Diagram label on product.
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Wire cap,  
3 places
Junction box
To house circuit breaker 
panel or fuse box
UL/CSA approved 
NEMA strain relief
To range hood
3 Wire Connection to Junction Box
Cable Lock
A cable locking connector (not supplied) might 
also be required by local codes. Check with local 
requirements and codes, and purchase and install 
appropriate connector if necessary.
Cable Lock
Verify the Package Contents
Unpack the parts box and verify that all parts and 
accessories have been included. If any item is 
missing or damaged, please contact the dealer 
immediately. Do not install a damaged or incomplete 
appliance.
Make sure you have everything necessary for proper 