Installation guide
37
INSTALLATION
ENGLISH
The power cable connected to the unit should be complied with IEC 60245 or HD 22.4 S4 (This
equipment shall be provided with a cable set complying with the national regulation.
CAUTION
!
GN/YL
20 mm
35±5 mm
10±3 mm
Model Name
Area( mm
2
) Cable Type
Phase Capacity
1Ø
5 kW
4
H07RN-F
7 kW
9 kW
12 kW
614 kW
16 kW
3Ø
12 kW
414 kW
16 kW
For the 1-Phase
20 mm
GN/YL
35±5 mm
10±3 mm
For the 3-Phase
Use round pressure terminals for connections to the power terminal block.
When none are available, follow the instructions below.
- Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power
wiring may cause abnormal heat.)
- When connecting wiring which is the same thickness, do as shown in the figure below.
- For wiring, use the designated power wire and connect firmly, then secure to prevent outside
pressure being exerted on the terminal block.
- Use an appropriate screwdriver for tightening the terinal screws. A screwdriver with a small
head will strip the head and make proper tighterning impossible.
- Over-tightening the terminal screws may break them.
Round pressure terminal
Power wire
Connect same thickness
wiring to both sides.
It is forbidden to connect
two to one side.
It is forbidden to
connect wiring of
different thicknesses.
Precautions when laying power wiring
WARNING
• Make sure that the screws of the terminal are free from looseness.
!