Installation guide
14
GENERAL INFORMATION
ENGLISH
Model name and related information
*1 : tested under Eurovent Heating condition
(water temperature 30°C ’ 35°C at outdoor ambient temperature 7°C / 6°C)
*2 : tested under Eurovent Cooling condition
(water temperature 23°C ’ 18°C at outdoor ambient temperature 35°C / 24°C)
*3 : All appliances were tested at atmospheric pressure.
Model Name
Built-In
Electric
Heater(kW)
Power
Source
(Electric
Heater)
Capacity
Power
Source
(Unit)
Outdoor Unit Indoor Unit
Heating
(kW)
*1
Cooling
(kW)
*2
Phase Capacity Phase Capacity
1Ø
5 kW
1Ø
16 kW
6 (3+3)
220-240 V~
50 Hz
5.0 5.0
220-240 V~
50 Hz
7 kW 7.0 7.0
9 kW 9.0 9.0
12 kW 12.0 10.4
14 kW 14.0 12.0
16 kW
16.0 13.0
3Ø
12 kW
3Ø 9 (3+3+3)
380-415 V~
50 Hz
12.0 10.4
380-415 V~
50 Hz
14 kW 14.0 12.0
16 kW 16.0 13.0