User’s Guide L1900J L1900R L1900E Make sure to read the Important Precautions before using the product. Keep the User's Guide(CD) in an accessible place for future reference. See the label attached on the product and quote this information to your dealer when you require service.
Important Precautions This unit has been engineered and manufactured to ensure your personal safety, however improper use may result in potential eletrical shock or fire hazards. In order to allow the proper operation of all safeguards incorporated in this display, observe the following basic rules for its installation, use, and servicing. On Safety Use only the power cord supplied with the unit.
Important Precautions On Installation Do not allow anything to rest upon or roll over the power cord, and do not place the display where the power cord is subject to damage. Do not use this display near water such as near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. Displays are provided with ventilation openings in the cabinet to allow the release of heat generated during operation.
Connect with a computer. Using the Computer 1. Connect the signal cable. When attached, tighten the thumbscrews to secure the connection. 1 A Connecting with DVI-Analog signal input cable B Connecting with DVI-Digital signal input cable 2. Use after connecting power cable 2 to AC-DC power adapter 3 and inserting it into outlet(Voltage is automatically controlled.) Tip Product color represented here may differ from actual product color that customer purchased.
Connecting the Display 3. Touch button on the front switch panel to turn the power on. When monitor power is turned on, the 'Self Image Setting Function' is executed automatically. (Only Analog Mode) NOTE ‘ Self Image Setting Function’? This function provides the user with optimal display settings.When the user connects the monitor for the first time, this function automatically adjusts the display to optimal settings for individual input signals.
Install Forte Manager program. This product provides a program(Forte Manager CD) which makes users convenient to adjust various screen conditions including Brightness, Tracking or Resolution by using mouse, without adjusting each button. Tip This software requires Microsoft Internet Explorer 6.0 or greater. ■ Forte Manager Program Installation Procedure 1) Close all other applications before installing Forte Manager program.
Install Forte Manager program. ■ Forte Manager Program Function To change or adjust Tracking, Brightness, Contrast, Position, Resolution, Sharpness or Preset of Display, use or select Forte Manager program. *Tracking and Position are supported only when signal is in analog mode. PICTURE - Tracking, Brightness, Contrast, Position, Resolution, Sharpness, Wizard, Preset f-Engine - MOVIE, TEXT, NORMAL, USER, Preset Color - Color Temp.
Control Panel Functions L1900E Front Panel Controls Control Power Button Rear Function Product may be turned on when you touch the button, and turned off when you touch it once again. * Check Power Indicator after touching Power Button. Power Indicator Power indicator is blue or red when the product is on, and it automatically blinks in Sleep mode(Energy Saving.
Control Panel Functions L1900J L1900R Front Panel Controls Control Power Button Function Product may be turned on when you touch the button, and turned off when you touch it once again. Power Indicator is blue or red when the product is on Power Indicator and it automatically repeats from dark to bright mode in Sleep mode (Energy Saving). [L1900J] The button underneath the picture is for adjusting brightness of Power Indicator.
DDC/CI ON/OFF Function DDC/CI(Display Data Channel Command Interface) is communication protocol for communications between PC and monitor. DDC/CI makes it possible to adjust and setup detailed functions on PC instead of the monitor OSD. Monitor can be adjusted with PC by connecting communication between PC and monitor when DDC/CI is ON, and monitor cannot be adjusted with PC because communication between PC and monitor is disconnected when DDC/CI is OFF.
Troubleshooting Check the following before calling for service. No image appears Is the power cord of the display connected? Check and see if the power cord is connected properly to the power outlet. Does power indicator blink or from dark to bright mode is repeated? If the display is in power saving mode, try moving the mouse or pressing any key on the keyboard to bring up the screen. Try to turn on the PC.
Troubleshooting Display image is incorrect Display Position is incorrect. On the screen background, vertical bars or stripes are visible. Press Forte Manager Program --> Picture --> Tracking-->Auto Setup to adjust screen automatically to the optimal condition, which fits to the current mode.
Troubleshooting Have you installed the display driver? Have you installed the display driver? Be sure to install the display driver from the display driver CD (or diskette) that comes with your display. Or, you can also download the driver from our web site: http://www.lge.com. Do you see an "Unrecognized monitor, Plug&Play (VESA DDC) monitor found" message? Make sure to check if the video card supports Plug&Play function.
Specifications Display Sync Input 19 inches (48.19cm) Flat Panel Active matrix-TFT LCD Anti-Glare coating 19 inches viewable 0.294mm pixel pitch Horizontal Freq. 30 - 83kHz (Analog) 30 - 71kHz (Digital) Vertical Freq.
Specifications Preset Modes (Resolution) Display Modes (Resolution) 1 2 3 4 5 6 7 8 9 10 11 *12 **13 VGA VGA VGA VESA VESA VESA MAC VESA VESA MAC VESA VESA VESA Horizontal Freq. (kHz) 31.469 31.468 31.469 37.500 37.879 46.875 49.725 48.363 60.023 68.681 61.805 63.981 79.
Specifications Kensington Security Kensington Security Slot Connected to a locking cable that can be purchased separately at most computer stores Tip Product color represented here may differ from actual product color that customer purchased.
Digitally yours