$FRXVWLF'DWD
MULTI F OUTDOOR UNIT
Table 19: Sound Power Levels (dB[A]).
Model No.
Sound Power Level (dB[A])
Cooling
LMU183HV 63
LMU243HV 64
LMU303HV 64
LMU363HV 64
Sound Power Levels
Data is valid under diffuse field conditions.
Data is valid under nominal operating conditions.
Sound power level is measured using rated conditions, and tested
in a reverberation room per ISO 3741 standards.
Sound level will vary depending on a range of factors such as
construction (acoustic absorption coefficient) of particular area in
which the equipment is installed.
5HIHUHQFH DFRXVWLF LQWHQVLW\ G% (ȝ:P
2
Figure 16: Sound Power Level Diagrams.
LMU243HVLMU183HV LMU303HV
10
20
30
40
50
60
70
80
90
100
125 250 500 1000 2000 4000 8000
Sound Power Level (0dB = 10E-6ȝW/m
2
)
NR-70
NR-65
NR-60
NR-55
Octave Band Center Frequency (Hz)
NR-50
NR-45
NR-40
NR-35
NR-30
NR-75
NR-25
NR-20
NR-80
NR-85
NR-90
Cooling
10
20
30
40
50
60
70
80
90
100
110
120
125 250 500 1000 2000 4000 8000
NR-70
NR-65
NR-60
Sound Power Level (0dB = 10E-6ȝW/m
2
)
NR-55
Octave Band Center Frequency (Hz)
NR-50
NR-45
NR-40
NR-35
NR-30
NR-75
NR-25
NR-20
NR-80
NR-85
NR-90
NR-95
Cooling
NR-100
NR-105
NR-110
10
20
30
40
50
60
70
80
90
100
110
125 250 500 1000 2000 4000 8000
NR-70
NR-65
NR-60
Sound Power Level (0dB = 10E-6ȝW/m
2
)
NR-55
Octave Band Center Frequency (Hz)
NR-50
NR-45
NR-40
NR-35
NR-30
NR-75
NR-25
NR-20
NR-80
NR-85
NR-90
NR-95
Cooling
NR-100
NR-105
NR-110
LMU363HV
10
20
30
40
50
60
70
80
90
100
125 250 500 1000 2000 4000 8000
Sound Power Level (0dB = 10E-6ȝW/m
2
)
NR-70
NR-65
NR-60
NR-55
Octave Band Center Frequency (Hz)
NR-50
NR-45
NR-40
NR-35
NR-30
NR-75
NR-25
NR-20
NR-80
NR-85
NR-90
Cooling