Multi F Installation Guide

Installation Manual 47
Function
ENGLISH
If you set the Dip Switch when power is on, the change in setting is not applicable. The changing set-
ting is enabled only when Power is reset.
Dip Switch
Function
1234
Normal Operation (No Function)
Forced Cooling Operation
Wiring Error Check
Saving Power Consumption (Step 1)
Saving Power Consumption (Step 2)
Mode Lock (Cooling)
Mode Lock (Heating)
Night Quiet Mode (Step 1)
Night Quiet Mode (Step 2)
Mode Lock (Cooling) + Night Quiet Mode (Step 1)
Mode Lock (Cooling) + Night Quiet Mode (Step 2)
Mode Lock (Cooling) + Saving Power Consumption (Step 1)
Mode Lock (Cooling) + Saving Power Consumption (Step 2)
Mode Lock (Heating) + Saving Power Consumption (Step 1)
Mode Lock (Heating) + Saving Power Consumption (Step 2)
Function
Dip S/W Setting
WARNING: When you set the dip switch, you should turn off the circuit
breaker or shut the power source of the product down.
CAUTION
• Unless the applicable dip switch is set properly, the product may not
work.
• If you want to set a specific function, request that the installer sets the
dip switch appropriately during installation.