LGRED Heat General Service Manual

Part 5. Trouble Shooting
- 43 -
Copyright ©2017 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1.2 Error Indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
1 Time 1 Time 1 Time
2 Times2 Times2 Times
1 Sec.
2 Sec. 2 Sec.
1 Sec. 1 Sec.
LED01G
(RED)
LED02G
(GREEN)
:
A light on the display panel is blink.
Error
Code
Contents
LED01G/M
(Red)
LED02G/M
(Green)
case of Error
Outdoor
Status
21 DC Link Peak (IPM Fault)
2times 1times
Over Rated Current
Off
22 CT 2 (Max CT)
2times 2times
Input Over Current
Off
23
DC Link Low Volt.
2times 3times
DC Link Volt is below 140Vdc
Off
DC Link High Volt.
DC Link Volt is above 420Vdc
25 Low Voltage/Over Voltage
2times 5times
Abnormal AC Volt Input
Off
26 DC Compressor Position Error
2times 6times
Compressor Starting Fall Error
Off
27 PSC/PFC Fault Error
2times 7times
Over Inverter PCB input current
Off
29 COMP Over Current
2times 9times
Over Inverter Compressor Current
Off
32 D-Pipe High
3times 2times
D-Pipe Temp. High
Off
35 Low Pressure Error
3times 5times
Excessive decrease of Low Pressure
Off
39 Communication Error
3times 9times
Communication Error Between PFC
Micom and INV Micom
Off
40 CT Sensor (Open/Short)
4times
CT Circuit Malfunction
Off
41 INV. D-Pipe Th Error
4times 1times
Open/Short
Off
43 High Pressure Sensor Error
4times 3times
Open/Short
Off
44 Outdoor Air Th Error
4times 4times
Open/Short
Off
45 Cond. Mid-Pipe Th Error
4times 5times
Open/Short
Off
46 Suction Pipe Th Error
4times 6times
Open/Short
Off
48 Cond. Out-Pipe Th Error
4times 8times
Open/Short
Off
51 Capacity Over
5times 1times
Over combination
Off
53 Signal Error (Indoor <-> Outdoor)
5times 3times
Communication Poorly
Off
54 3-Phase Wrong wiring
5times 4times
3-Phase Wrong Wring of Outdoor Unit
(Reverse Phase/Omission of Phase)
Off
60 EEPROM Check Sum Error
6times
Check Sum Mismatching
Off
61 Cond. Pipe Th High
6times 1times
Cond. Temp. High
Off
62 Heaksink Th High
6times 2times
Heatsink Temp. High
Off
65 Heaksink Th Error
6times 5times
Open/Short
Off
67 Outdoor BLDC Fan Lock
6times 7times
Outdoor Fan is not operation
Off
73 PFC Fault Error(S/W)
7times 3times
Over Current of Outdoor Unit PFC
Off