Installation
When you connect the refrigerant pipe, it is easier that you connect the gas pipe first.
1. Hold up the Sensor Link.
2. Separate the Pipe Bracket (2 screws)
3. Connect the refrigerant pipe. (Refer to next page)
4. Assemble the Pipe Bracket (2 screws)
5. Put down the Sensor Link.
6. After connecting, check the pipe arrangement as per illustration.
7. The piping can be arranged in six ways as shown in the illustration below.
Connecting the Piping
3
1
2
6
5
4
Pipe Guide
Pipe Guide
Connecting Pipe must be placed inner
than the pipe guide.
Connecting
Connecting
Pipe
Pipe
Connecting
Pipe