Floor Standing Installation Manual

Installation Manual 9
ENGLISH
Installation
1. There should not be any heat or steam near the unit.
2. Select a place where there are no obstacles around of the unit.
3. Make sure that condensation drainage can be conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left (or right) of the unit is more than 11-13/16"
(300mm).
6. Use a metal detector to locate studs to prevent unnecessary damage to the wall.
7. Keep away from electronic ignition type fluorescent lamps as they may shorten the remote
controller range.
8.
Please check at least 3.3ft (1m) away from television or radio.(It cause interference with the picture or
sound.)
Choosing an installation Site
9-27/32 (250) or below
from the Floor
More than
11-13/16 (300)
[Unit : inch (mm)]
More than
11-13/16 (300)
More than
11-13/16 (300)
• Before choosing the installation site, please obtain user approval.
If the unit is installed below a window,check the interference of window curtain.
[more than 11-13/16”(300mm)]
NOTICE