Multi F Outdoor Unit Engineering Manual

Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
16 | MULTI F OUTDOOR UNIT
Multi F and Multi F MAX Heat Pump System Engineering Manual
MULTI
F
MAX
MULTI
F
The multiple piping of Multi F systems can support two, three or four indoor units that are typically mounted in separate rooms. Compact
refrigerant pipes work in tandem with wiring to link the outdoor unit with all indoor units directly. Most indoor units include its own remote
control, allowing the user to set the temperature individually in different rooms. The indoor units are available in a variety of capacities and
styles, including Art Cool™ Mirror and Gallery Wall Mounts, Standard Wall Mount, Four-Way Ceiling Cassette, Horizontal Ceiling Concealed
Duct, and Vertical-Horizontal Air Handling models.
•Defrost
•Restart delay (three [3] minutes)
•Self diagnosis
•Soft start
•Inverter (Variable speed compressor)
•Low ambient operation to 14ºF (Cooling
mode)
•Auto operation / auto restart operation
•Gold Fin™ anti-corrosion
•Outdoor unit includes sufficient refrigerant
for charging two (2), three (3), or four (4)
indoor units using 24.6 feet of pipe to each
Figure 1: Dual-Zone Multi F Heat Pump
Inverter System — Mix and match for
9,000-24,000 Btu/h.
Figure 3: Quad-Zone Multi F Heat Pump
Inverter System — Mix and match for
18,000-48,000 Btu/h.
Benefits
•Long refrigerant piping lengths allow for extra design flexibility in indoor unit placement
•Easy installation: Little to no ductwork required; most indoor units can mount on any wall
•Indoor unit and outdoor unit dimensions ensure space saving convenience
•All-season use—heat pump models have both cooling and heating capabilities
MULTI F SYSTEMS
Features and Benets
Features
Figure 2: Tri-Zone Multi F Heat Pump
Inverter System — Mix and match for
12,000-33,000 Btu/h.