Unpack and Inspect for Freight Damage
CAUTION
6KLSSLQJDQGQHWZHLJKWVRIWKHZDOOPRXQWHGXQLWVDUHOLVWHGLQWKHVSHFL¿FDWLRQVWDEOH7RKHOSDYRLGLQMXU\WRSHUVRQQHODQGGDPDJHWRWKHXQLW
use two people when carrying a unit by hand.
Shipping and net weights of the ceiling cassette units are listed in the specification tables in the beginning of this manual. To help avoid dam-
age to the unit, use at least two people when carrying a unit by hand.
Before opening the shipping container, check the container labeling to verify the unit received is the correct unit. Verify the unit capacity, type,
and voltage. Refer to the “Unit Nomenclature” chart in the beginning of this manual.
• After opening, if the unit is damaged, repack the unit as it was shipped to you. RETAIN ALL PACKING MATERIALS. In general, freight damage
claims will be denied if the original packing materials are not retained for the claims adjustor to inspect. Contact your supervisor on how to
proceed with filing a freight claim and to order a replacement unit.
• To avoid damaging the indoor unit,
do not unpack the unit and remove the protective materials until it is ready to install. Before unpacking,
carefully move the packaged unit to a work area near the installation location.
1. Before opening the shipping container, verify that the correct unit is present as described in the Note above.
2. Place the box on a solid surface right side up.
3. Cut the white reinforced nylon straps.
4. Open the top of the box and fold back all four flaps.
5. Remove the protective cardboard / Styrofoam
®
top sheet and place to the side.
6. The walls and top panels are not attached to the bottom of the box. Lift the cardboard carton by the flaps and remove the box walls and
top and place it to the side.
7. Remove the moisture barrier plastic bonnet.
8. Check the unit nameplate data and model number. Verify the unit voltage and capacities are correct before proceeding.
9. Locate and retain the included parts located in the box.
10. Using two people, carefully lift the unit and inspect for freight damage.
DO NOT lift by the refrigerant piping or drain pipe stub. Lift by
the frame only. If damage is found, repack the unit as it was received in the original container.
INSTALLATION