Engineering Manual

Table Of Contents
Model No. /
Nominal Capacity
of Indoor Unit
(Btu/h)
Outdoor Air
Temp.
(°F DB)
Indoor Air Temp. °F DB / °F WB
68 / 57 73 / 61 77 / 64 80 / 67 86 / 72 90 / 75
TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
LMAN187HVT
18,000
14 17.65 12.33 18.74 13.02 19.84 12.61 20.63 12.88 22.03 12.98 23.12 13.23
20 17.63 12.43 18.73 13.13 19.82 12.71 20.61 12.98 22.01 13.09 23.11 13.33
25 17.62 12.52 18.71 13.23 19.81 12.81 20.60 13.08 22.00 13.19 23.09 13.44
30 17.60 12.62 18.70 13.33 19.79 12.91 20.58 13.18 21.98 13.29 23.07 13.54
35 17.59 12.71 18.68 13.43 19.78 13.00 20.57 13.28 21.96 13.39 23.05 13.64
40 17.58 12.81 18.67 13.53 19.76 13.10 20.55 13.38 21.94 13.49 23.04 13.75
45 17.56 12.90 18.66 13.63 19.75 13.20 20.53 13.48 21.93 13.59 23.02 13.85
50 17.55 13.00 18.64 13.73 19.73 13.30 20.52 13.58 21.91 13.69 23.00 13.95
55 17.54 13.10 18.63 13.83 19.72 13.39 20.50 13.68 21.89 13.79 22.98 14.05
60 17.52 13.19 18.61 13.93 19.70 13.49 20.49 13.78 21.88 13.89 22.97 14.16
65 17.51 13.29 18.60 14.03 19.69 13.59 20.47 13.87 21.86 13.99 22.95 14.26
70 17.50 13.38 18.58 14.13 19.67 13.69 20.46 13.97 21.84 14.09 22.93 14.36
75 17.08 13.16 18.16 13.92 19.24 13.49 20.03 13.79 21.41 13.92 22.50 14.20
80 16.66 12.93 17.74 13.70 18.82 13.30 19.60 13.60 20.98 13.75 22.06 14.03
85 16.24 12.70 17.32 13.47 18.40 13.09 19.17 13.40 20.55 13.56 21.63 13.85
90 15.82 12.46 16.90 13.23 17.97 12.88 18.75 13.19 20.12 13.37 21.20 13.67
95 15.37 12.33 16.44 13.12 17.51 12.78 18.00 12.90 19.65 13.30 20.72 13.61
100 14.99 12.00 16.06 12.78 17.13 12.47 17.77 12.70 19.28 13.01 20.35 13.33
105 14.62 11.67 15.69 12.45 16.76 12.17 17.53 12.50 18.90 12.73 19.97 13.05
110 14.24 11.27 15.32 12.05 16.39 11.79 17.16 12.13 18.53 12.36 19.60 12.70
115 13.87 10.93 14.94 11.71 16.01 11.48 16.79 11.82 18.15 12.07 19.22 12.41
118 13.65 10.85 14.72 11.64 15.79 11.42 16.56 11.77 17.93 12.03 19.00 12.37
122 13.57 10.83 14.64 11.62 15.71 11.40 16.49 11.75 17.85 12.01 18.92 12.36
Table 14: Multi F Art Cool Mirror Indoor Units Cooling Capacity Table (continued).
TC = Total Capacity (kBtu/h).
SHC: Sensible Heat Capacity (kBtu/h).
Nominal capacity as rated 0 ft. above sea level and a 0 ft. level difference between outdoor and indoor
units. Corresponding refrigerant piping length is accordance with standard length of each outdoor unit.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and
67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
The shaded table columns and rows indicate reference data. When operating at this temperature, these
values can be different if the system is not running consistently.
Cooling Capacity Table
ART COOL MIRROR INDOOR UNITS
ART COOL MIRROR | 21
Art Cool Mirror™
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F