Engineering Manual

Table Of Contents
ART COOL MIRROR INDOOR UNITS
Installation and Best Layout Practices
Wired controllers include a sensor to detect room temperature. To maintain comfort
levels in the conditioned space, the wired controller must be installed in a location
away from direct sunlight, high humidity, and where it could be directly exposed to
cold air. Controller must be installed four (4) to five (5) feet above the floor where its
LED display can be read easily, in an area with good air circulation, and where it can
detect an average room temperature.
Do not install the wired controller near or in:
Drafts or dead spots behind doors and in corners
Hot or cold air from ducts
Radiant heat from the sun or appliances
Concealed pipes and chimneys
An area where temperatures are uncontrolled, such as an outside wall
Figure 32:Wired Controller Connection on the Indoor Unit Terminal
Block—LMAN097HVT and LMAN127HVT models.
Indoor Unit Terminal Block
1(L1 )2(L2)
GND
GRN / YLW
BR
BL
RD
CN-REMO
To Outdoor Unit or Branch Distribution Unit
(Multi F MAX Systems Only)
To Wired Controller
3
Figure 33:Wired Controller Connection on the Indoor Unit Terminal
Block—LMAN187HVT models.
Figure 34:Proper Location for the Wired Controller.
Indoor Unit Terminal Block
1(L1 )2(L2)
GND
GRN / YLW
BR
BL
RD
CN-REMO
To Outdoor Unit or Branch Distribution Unit
(Multi F MAX Systems Only)
To Wired Controller
3
Wired Controller Connections
Wired Controller Placement
4 to 5 feet
above the floor
NO
NO
NO
YES
Remote Controller
TEMP
Remote Controller
TEMP
Re
m
ot
e
C
o
n
t
r
ol
l
er
TEMP
ART COOL MIRROR | 35
Art Cool Mirror™
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F