Mini Split Brochure

How LG Multi F systems work for you:
LG multi-zone systems bring all the benets of an energy efcient air conditioning system with the convenience of multiple
personalized comfort zones within your home. Customize not only your temperature setting but also your indoor unit
design style, reliable heating performance for year-round comfort, controller selection for each zone including remote
access via mobile, and much more.
PB_MultiZone_HCS_6_19
Note:
1. Rated capacity at 0 ft. above sea level with 25 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor unit.
2. Rated cooling capacity obtained with air entering the indoor unit at 80˚F dry bulb (DB) and 67˚F wet bulb (WB) and outdoor ambient conditions of 95˚F dry bulb (DB) and 75˚F wet bulb (WB).
Rated heating capacity obtained with air entering the indoor unit at 70˚F dry bulb (DB) and 60˚F wet bulb (WB) and outdoor ambient conditions of 47˚F dry bulb (DB) and 43˚F wet bulb (WB).
For capacity information, see engineering manual capacity tables. Capacities are based on connection of Non-Ducted indoor units.
3. All power/communication wiring minimum 4-conductor, stranded, shielded, and must comply with applicable local and national codes.
4. Due to our policy of innovation, some specications may be changed without notication.
©2019 LG Electronics USA, Inc. . All rights reserved. “LG Lifes Good” is a registered trademark of LG Corporation.
Multi-Zone Home Comfort Solutions
Air Conditioning Technologies | lghvac.com
Visit lghvac.com to locate LG installers in your area.
LG Electronics USA Inc., Air Conditioning Technologies
4300 North Point Parkway, Alpharetta, GA 30022
SEER: Your guide to cool savings
An acronym for Seasonal Energy Efciency Ratio, SEER is
the industry-wide rating measurement that conveys energy
consumption information to consumers. The higher the
number, the more efciently a product will produce cool
air…and operating efciency is a big step in conserving our
natural resources. Your contractor will be happy to explain
SEER numbers in greater detail, and help you determine
which LG system is best for your unique requirements
.
HSPF: For cost-saving coziness
Heating Seasonal Performance Factor, or HSPF, represents
the total heating output when compared to the electricity
used. Like SEER, the higher the HSPF rating, the more
efciently a product will produce warm air. If you live in
a climate that requires heating in the winter months as
well as cooling in the summer, ask your contractor to help
determine the ideal LG system for you.
ENERGY STAR
®
is a joint program of the U.S. Environmental Protection Agency (EPA) and the U.S. Department
of Energy (DOE) created to promote energy-efcient products and practices. The ENERGY STAR
®
logo helps
homeowners identify which products meet energy efciency performance levels set by U.S. EPA and U.S. DOE
.
100%
heating
capacity
down to 5° F
Continuous heating down to -13° F
19dB
Forest
26dB
22dB
Conventional
Inverter
32dB
Conventional
On/Off
36dB
Library
17 dB(A)
LG AC Indoor Unit as
low as 17 dB(A)
Art Cool Premier
(Sleep Mode)
40
dB(A)
Bird Calls
50
dB(A)
Conversation
at Home
Indoor Unit
60
dB(A)
Conversation
in Restaurant
70
dB(A)
Vacuum
Cleaner
Year-Round Comfort
heating down to -13˚ F
Remote Access
control your comfort
Quiet Operation
inside and out
Congurable Systems
best t in the space
Indoor Unit Styles
with style
Controller Options
On/Off to scheduling
MULTI F OUTDOOR UNITS MULTI F with LGRED°
Specication Unit LMU480HV LMU540HV LMU600HV LMU360HHV LMU420HHV
Capacity
ENERGY STAR®
Matched Systems
Non-Ducted
Non-Ducted
& Ducted
Non-Ducted
& Ducted
Rated Cooling Capacity Btu/h 48,000 52,500 60,000 36,000 42,000
Cooling Capacity Range Btu/h 14,400 ~ 58,000 14,400 ~ 63,200 15,600 ~ 68,000 11,700 ~ 46,733 11,700 ~ 53,897
Rated Heating Capacity Btu/h 54,000 58,000 64,000 41,000 45,000
Heating Capacity Range Btu/h 15,840 ~ 61,000 16,272 ~ 64,000 17,940 ~ 70,000 13,455 ~ 50,200 13,455 ~ 55,256
Max. Heating Capacity at 17˚F Btu/h 49,014 51,832 53,560 45,510 49,950
Max. Heating Capacity at 5˚F Btu/h 38,900 41,137 42,720 41,000 45,000
Max. Heating Capacity at -4˚F Btu/h 27,529 29,112 33,193 36,900 39,150
Max. Heating Capacity at -13˚F Btu/h - - - 32,390 34,200
SEER / EER 19.5 / 12.5 18.4 / 10.3 20.5 / 11.4 21 / 15 20.5 / 14
HSPF 10.0 8.7 11.0 11.5 11.0
Power
Voltage V - Ø - Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Cooling Power Input kW 3.84 5.1 5.26 2.4 3
Heating Power Input kW 4.32 5.4 5.33 2.93 3.3
MCA / MOCP A 27.3 / 40 29.4 / 40 32.2 / 45 30.2 / 45 30.2 / 45
Power/Communication Wiring
3
No. x
AWG
ODU
> BDU: 4 x 16
BDU
> IDU: 4 x 18
ODU
> BDU: 4 x 16
BDU
> IDU: 4 x 18
ODU –> BDU: 4 x 16
BDU –> IDU: 4 x 18
ODU
> BDU: 4 x 16
BDU
> IDU: 4 x 18
ODU
> BDU: 4 x 16
BDU
> IDU: 4 x 18
Dimensions
& Weight
Dimensions (W x H x D) in. 37
13
/
32
x 54
11
/
32
x 13 37
13
/
32
x 54
11
/
32
x 13 37
13
/
32
x 54
11
/
32
x 13 37
13
/
32
x 54
11
/
32
x 13 37
13
/
32
x 54
11
/
32
x 13
Weight (Net/Shipping) lbs 214/236 214/236 223/249 222.7/249.1 222.7/249.1
Unit Data
Min. Connectable Indoor Units Qty 2 2 2 2 2
Max. Connectable Indoor Units Qty 8 8 8 5 6
Max. Indoor Connected Capacity Btu/h 65,000 73,000 81,000 48,000 56,000
Specication Unit LMU18CHV LMU24CHV LMU30CHV LMU36CHV LMU180HHV LMU240HHV LMU300HHV
Capacity
ENERGY STAR®
Matched Systems
Non-Ducted
Non-Ducted
Mixed Non-Duct-
ed & Ducted
Non-Ducted
Mixed Non-Duct-
ed & Ducted
Non-Ducted
Mixed Non-Duct-
ed & Ducted
Non-Ducted Non-Ducted Non-Ducted
Rated Cooling Capacity Btu/h 17,000 20,000 30,000 32,000 18,000 24,000 28,400
Cooling Capacity Range Btu/h 8,400 ~ 19,000 8,400 ~ 25,000 8,400 ~ 36,000 8,400 ~ 38,400 8,400 ~ 19,980 8,400 ~ 30,000 8,400 ~ 34,080
Rated Heating Capacity Btu/h 22,000 24,000 32,000 36,000 22,000 26,000 28,600
Heating Capacity Range Btu/h 10,248 ~ 24,000 9,240 ~ 28,800 9,240 ~ 38,400 9,240 ~ 41,600 10,248 ~ 24,000 10,248 ~ 31,200 10,248 ~ 34,320
Max. Heating Capacity at 17˚F Btu/h 19,161 21,097 26,739 29,105 23,600 28.500 31,600
Max. Heating Capacity at 5˚F Btu/h 14,807 14,595 20,622 22,057 22,000 26,000 28,600
Max. Heating Capacity at -4˚F Btu/h 9,912 10,385 13,753 15,823 21,050 23,880 25,550
Max. Heating Capacity at -13˚F Btu/h - - - - 19,270 21,310 22,210
SEER / EER 22.0 / 13.0 21.7 / 13.5 22.0 / 13.0 22.0 / 13.0 21.0 / 13.5 21.0 / 13.5 20.0 / 12.5
HSPF 9.7 10.6 10.0 10.0 10.0 10.7 11.0
Power
Voltage V - Ø - Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Cooling Power Input kW 1.31 1.48 2.31 2.46 1.33 1.78 2.27
Heating Power Input kW 2.04 1.80 2.49 2.74 2.22 2.12 2.33
MCA / MOCP A 13.3 / 20 14.3 / 20 16.6 / 25.0 17.9 / 25 18.6 / 30 19 / 30 19.4 / 30.0
Power/Communication Wiring
3
No. x
AWG
4 x 18 4 x 18 4 x 18 4 x 18 4 x 18 4 x 18 4 x 18
Dimensions
& Weight
Dimensions (W x H x D) in. 34
1
/
4
x 25
25
/
32
x 12
19
/
32
34
1
/
4
x 25
25
/
32
x 12
19
/
32
37
13
/
32
x 32
27
/
32
x 13 37
13
/
32
x 32
27
/
32
x 13 37
13
/
32
x 32
27
/
32
x 13 37
13
/
32
x 32
27
/
32
x 13 37
13
/
32
x 32
27
/
32
x 13
Weight (Net/Shipping) lbs 100/108 100/108 137/148 137/148 147.7/163.1 152.1/165.3 152.1/165.3
Unit Data
Min. Connectable Indoor Units Qty 2 2 2 2 2 2 2
Max. Connectable Indoor Units Qty 2 3 4 4 2 3 4
Max. Indoor Connected Capacity Btu/h 24,000 33,000 40,000 48,000 24,000 33,000 40,000
MULTI F MAX OUTDOOR UNITS MULTI F MAX with LGRED°