Engineering Manual
Table Of Contents
- Convergence of Technology, Innovation, Flexibility, & Style
 - Unit Nomenclature
 - Outdoor Unit Overview
 - Indoor Unit Overview
 - Controls and Options Overview
 - Art Cool Mirror Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - Acoustic Data
 - Air Velocity and Temperature Distribution
 - Refrigerant Flow Diagram
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Art Cool Gallery Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - Acoustic Data
 - Air Velocity and Temperature Distribution
 - Refrigerant Flow Diagram
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Standard Wall-Mounted Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - Acoustic Data
 - Air Velocity and Temperature Distribution
 - Refrigerant Flow Diagram
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Duct (Low Static) Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - External Static Pressure
 - Acoustic Data
 - Refrigerant Flow Diagrams
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Duct (High Static) Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - External Static Pressure / Acoustic Data
 - Refrigerant Flow Diagrams
 - Wiring Diagrams
 - Factory Supplied Parts and Materials / Installation
 - Installation and Best Layout Practices
 - Four-Way Ceiling Cassette Indoor Units
 - General Data / Specifications
 - Dimensions
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - Acoustic Data
 - Air Velocity and Temperature Distribution
 - Refrigerant Flow Diagram
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Vertical-Horizontal Indoor Units
 - General Data / Specifications
 - Dimensions
 - Cooling Capacity Table
 - Heating Capacity Table
 - External Static Pressure
 - Acoustic Data
 - Refrigerant Flow Diagram
 - Wiring Diagram
 - Factory Supplied Parts and Materials
 - Installation and Best Layout Practices
 - Equipment Selection Procedure
 - Building Ventilation Design Guide
 - Placement Considerations
 - Refrigerant Piping Design
 - Design Guideline Summary
 - Creating a Balanced System / Manual Layout Procedure
 - LG Engineered Multi F MAX Y-Branch Kit
 - Refrigerant Charge
 - Installation & Layout Best Practices
 - Refrigerant Piping System Layout
 - Piping Insulation
 - Condensate Drain Piping
 - Y-Branch Kit
 - Wiring Connections
 - Power Wiring (208-230V) and Communications Cable Details
 - Indoor Unit Group Control
 - Acronyms
 
Controller Options
Art Cool Mirror wall-mounted indoor units include a wireless controller (AKB73635606), but optional LG-supplied wired controllers are avail-
able (see Controls and Options overview on pages 9 to 12 in this manual’s Introduction section).
ART COOL MIRROR INDOOR UNITS
Installation and Best Layout Practices
Display 
Screen
Figure 31:AKB73635606 Wire-
less Controller.
1
Depending on the indoor unit model, some functions may not be supported.
Control  
Panel
Table 20: AKB73635606 Wireless Controller Functions.
Control 
Panel 
Button
Display 
Screen
Description
Plasma Button: Plasma filter helps remove air impurities.
Sleep Mode Button
1
: Sets the sleep mode auto operation.
Temperature Adjustment Buttons: Raises or lowers temperature setpoint in
cooling and heating operation.
On / Off Button: Turns the power on/off.
Indoor Fan Speed Button: Changes the fan speed.
Operation mode selection button
1
: Selects the operation mode. 
Cooling operation   / Auto operation or auto changeover   / 
Dehumidifying operation / Heating operation / Air circulation
Jet Cool / Jet Heat Button
1
: Warms up or cools down the indoor 
temperature within a short period.
Air Flow Direction Button: Adjusts the airflow direction vertically or 
horizontally.
Temperature Display Button: Displays the room temperature. Press and
hold button down for five (5) seconds. Display changes from °C to °F.
Timer button: Sets the current time and the start / end times.
Navigation / Functions Button
1
: Adjusts the time and sets the special functions.
Auto clean / Operates energy saving cooling / Adjusts the brightness 
of the indoor unit display
Set / Clear Button: Sets or cancels functions.
Reset Button: Resets the air conditioner settings.
Wireless Handheld Controller
Operation Mode Sequence
Cooling Mode
↓
Auto Operation
↓
Dehumidification Mode
↓
Heating Mode
Due to our policy of continuous product innovation, some specications may change without notication.  
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
34 | ART COOL MIRROR
Multi F and Multi F MAX Indoor Unit Engineering Manual
MULTI 
F
MAX
MULTI 
F