Engineering Manual
Table Of Contents
- Convergence of Technology, Innovation, Flexibility, & Style
- Unit Nomenclature
- Outdoor Unit Overview
- Indoor Unit Overview
- Controls and Options Overview
- Art Cool Mirror Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- Acoustic Data
- Air Velocity and Temperature Distribution
- Refrigerant Flow Diagram
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Art Cool Gallery Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- Acoustic Data
- Air Velocity and Temperature Distribution
- Refrigerant Flow Diagram
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Standard Wall-Mounted Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- Acoustic Data
- Air Velocity and Temperature Distribution
- Refrigerant Flow Diagram
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Duct (Low Static) Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- External Static Pressure
- Acoustic Data
- Refrigerant Flow Diagrams
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Duct (High Static) Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- External Static Pressure / Acoustic Data
- Refrigerant Flow Diagrams
- Wiring Diagrams
- Factory Supplied Parts and Materials / Installation
- Installation and Best Layout Practices
- Four-Way Ceiling Cassette Indoor Units
- General Data / Specifications
- Dimensions
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- Acoustic Data
- Air Velocity and Temperature Distribution
- Refrigerant Flow Diagram
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Vertical-Horizontal Indoor Units
- General Data / Specifications
- Dimensions
- Cooling Capacity Table
- Heating Capacity Table
- External Static Pressure
- Acoustic Data
- Refrigerant Flow Diagram
- Wiring Diagram
- Factory Supplied Parts and Materials
- Installation and Best Layout Practices
- Equipment Selection Procedure
- Building Ventilation Design Guide
- Placement Considerations
- Refrigerant Piping Design
- Design Guideline Summary
- Creating a Balanced System / Manual Layout Procedure
- LG Engineered Multi F MAX Y-Branch Kit
- Refrigerant Charge
- Installation & Layout Best Practices
- Refrigerant Piping System Layout
- Piping Insulation
- Condensate Drain Piping
- Y-Branch Kit
- Wiring Connections
- Power Wiring (208-230V) and Communications Cable Details
- Indoor Unit Group Control
- Acronyms
Power Wiring (208-230V) and Communications Cable Details
1(L1) 2(L2)
1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2)
1(L1) 2(L2)
S
S S S S
1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2) 1(L1) 2(L2)
Indoor Unit Terminal Block
3 3
Outdoor Unit Terminal Block
L
L
N
N
G
Power Supply
Outdoor unit
Main Switch
Circuit Breaker
Three-wire Power Wiring
(Including Ground)
Fuse
* Same Wiring as Branch Distribution Unit (A)
S
Branch Distribution Unit (B)
3 3
COMMUNICATIONS CABLE
POWER WIRING
L1 L2
1(
L1
)2(
L2
)3(A ) 1(
L1
)2(
L2
)3(B)
Branch Distribution Unit (A)
Indoor Unit Terminal Block Indoor Unit Terminal Block Indoor Unit Terminal Block
Figure 311: Multi F MAX LMU540HV System Power Wiring and Communications Cable.
• All field-supplied wiring, components, and materials should follow national, state, and local codes and requirements.
• Use only stranded, shielded copper conductor.
• Ground wiring is required to prevent accidental electrical shock during current leakage, communication problems from electrical
noise, and motor current leakage. Do not connect the ground line to the pipes.
• Install a main shutoff switch or circuit breaker that interrupts all power sources simultaneously.
• Wiring cable size must comply with applicable national, state, and local codes.
WIRING CONNECTIONS
Due to our policy of continuous product innovation, some specications may change without notication.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
WIRING CONNECTIONS | 221
Wiring Connections
MULTI
F
MAX
MULTI
F