LCN098HV4 Submittal

Job Name/Locaon:
Date:
PO No.:
Architect: GC:
Engr: Mech:
Rep:
(Company) (Project Manager)
For: File Resubmit
Approval Other
Tag #:
For a complete list of available accessories, contact your LG representave.
For connual product development, LG reserves the right to change specicaons without noce.
© LG Electronics U.S.A., Inc., Englewood Clis, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
1. Acceptable operang voltage: 187V-253V.
2. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. Removable Washable Filter size: 14" x 14" x 1".
4. See Engineering Manual for sensible and latent capacies.
5. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied
and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be
grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
6. Power wiring cable size must comply with the applicable local and naonal code.
7. The indoor unit comes with a dry helium charge.
8. Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the
level dierence is 0 . All capacies are net with a combinaon rao between 95 - 105%.
9. Must follow installaon instrucons in the applicable LG installaon manual.
Notes:
Controls Features:
Two thermistor control
24-Hour on / o mer
Auto operaon
Auto restart
Chaos swing
Control lock funcon
Drain pump
Group control
Inverter (variable speed fan)
Jet cool
Compable with accessory Wi-Fi
module
Oponal Accessories:
Cooling (°F DB)
Heang (°F WB)
57 ~ 77
59 ~ 81
Entering Mixed Air:
Page 1 of 2
Included Accessories:
Wireless Remote Controller — AKB73757604
Performance:
Nominal Cooling Capacity (Btu/h)
Nominal Heang Capacity (Btu/h)
Cooling Nominal Test Condions:
Indoor: 80°F DB / 67°F WB
Outdoor: 95°F DB / 75°F WB
Heang Nominal Test Condions:
Indoor: 70°F DB / 60°F WB
Outdoor: 47°F DB / 43°F WB
Electrical:
Power Supply (V¹/Hz/Ø)
Rated Amps (A)
208-230/60/1
0.25
Piping:
Installed Liquid Pipe (in., O.D.)
Installed Vapor Pipe (in., O.D.)
Liquid Connecon (in., O.D.)
Vapor Connecon (in., O.D.)
Drain (in., O.D. / I.D.)
Temperature Sensor
1-1/4, 1
Thermistor
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure (H/M/L) dB(A)
2
Primary Filter
3
Net Weight (lbs.)
Shipping Weight (lbs.)
Grille Net Weight (lbs.)
Grille Shipping Weight (lbs.)
R410A
EEV
Washable Pre-lter
Fan:
Type
Quanty
Motor/Drive
Air Flow H/M/L (CFM)
Turbo
1
Brushless Digitally Controlled/Direct
Required Accessories:
Grille Kit (27-9/16" x 27-9/16") - PT-UQC, or
Grille Kit (24-7/16" x 24-7/16") - PT-QCHW0
MulSITE™ CRC1 Controller - PREMTBVC0
MulSITE™ CRC1+ Controller - PREMTBVC1
Simple Remote Controller - PREMTC00U
Premium Remote Controller - PREMTA000
AC Smart Premium - PQCSW421E0A
ACP Premium - PQCPC22A1
ACP Standard - PQCPC22N1
LonWorks® Gateway* - PQNFB16A1
BACnet® Gateway* - PQNFB17C1
Remote Temperature Buon Sensor - ZRTBS01
Simple Dry Contact (1 contact, 24 VAC external power) - PDRYCB100
Dry Contact for Third Party Thermostat - PDRYCB300
Dry Contact for Economizer - PDRYCB400
Plasma Filter Kit - PTPKQ0
Auxiliary Heater Kit - PRARH1
Wi-Fi Module - PWFMDD200
*BACnet® is a registered trademark of ASHRAE. LonWorks® is a registered trademark of Echelon Corporaon.
9,000
Multi F Ceiling Cassette Indoor Unit
ø3/8
9
ø1/4
ø3/8
29
10,400
36 / 33 / 30
ø1/4
SB_MultiF_FourWayCassette_LCN098HV4_2018_11_16_133735
7
300 / 265 / 230
LCN098HV4
• Compatible with applicable
Single Zone Outdoor Units (see
single zone literature for matching
system details)
9,000 Btu/h
34

Summary of content (2 pages)