Art Cool Premier Installation Manual

19
General Installation Guidelines
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
GENERAL INSTALLATION GUIDELINES
Required Indoor Unit Clearances
)ROORZUHTXLUHGEHVWSUDFWLFHVZKHQFKRRVLQJDQLQGRRUORFDWLRQIRUWKH
VLQJOH]RQH$UW&RRO3UHPLHULQGRRUXQLW
Do’s
Minimum clearance of indoor unit from the top of the unit to the
ceiling must be greater than 8 inches.
Clearance gap between any wall or enclosure and the left or right
side of the unit must be greater than 4 inches. Ensure there is suf-
ficient maintenance space.
8QLWPXVWEHDWOHDVWIHHWIURPWKHÀRRUIRUDGHTXDWHFOHDUDQFH
Place the unit where drainage can be obtained easily. Condensa-
tion drain must be conveniently routed away from the unit.
Locate the indoor unit in a location where it can be easily con-
nected to the outdoor unit within allowable limits.
Install the indoor unit on a strong, hard wall that can withstand its weight. Use a metal detector to locate studs in the walls. Anchor unit fol-
lowing stud location to prevent damage to the wall.
Do Not’s
Do not install the unit near a heat or steam source, or where considerable amounts of oil, iron powder, or flour are used. (These materials
will generate condensate, cause a reduction in heat exchanger efficiency, or the drain to malfunction. If this is a potential problem, install a
ventilation fan large enough to vent out these materials.)
(QVXUHWKHUHDUHQRREVWDFOHVWRDLUFLUFXODWLRQDURXQGWKHXQLWNHHSSURSHUGLVWDQFHVIURPFHLOLQJVGRRUZD\VIORRUZDOOVHWF
Do not install in an area where operation sound will disturb occupants--place the unit where noise prevention is taken into consideration
Do not install near doorway.
$YRLGLQVWDOOLQJWKHXQLWQHDUKLJKIUHTXHQF\JHQHUDWRUV
7KHXQLWPXVWQRWEHLQVWDOOHGZKHUHVXOIXULFDFLGDQGÀDPPDEOHRUFRU-
URVLYHJDVHVDUHJHQHUDWHGYHQWHGLQWRRUVWRUHG7KHUHLVULVNRI¿UH
explosion, and physical injury or death.
The unit will be damaged, will malfunction, and / or will not
operate as designed if installed in any of the conditions
listed.
,QGRRUXQLWV,'8VPXVWQRWEHSODFHGLQDQHQYLURQPHQWZKHUHWKH,'8VZLOOEHH[SRVHGWRKDUPIXOYRODWLOHRUJDQLFFRPSRXQGV92&V
RULQHQYLURQPHQWVZKHUHWKHUHLVLPSURSHUDLUPDNHXSRUVXSSO\RULQDGHTXDWHYHQWLODWLRQ,IWKHUHDUHFRQFHUQVDERXW92&VLQWKHHQYL-
URQPHQWZKHUHWKH,'8VDUHLQVWDOOHGSURSHUDLUPDNHXSRUVXSSO\DQGRUDGHTXDWHYHQWLODWLRQPXVWEHSURYLGHG$GGLWLRQDOO\LQEXLOGLQJV
ZKHUH,'8VZLOOEHH[SRVHGWR92&VFRQVLGHUDWKLUGSDUW\IDFWRU\DSSOLHGHSR[\FRDWLQJWRWKHIDQFRLOVIRUHDFK,'8ZKHUHWKHHQWLUHFRLO
is dipped, not sprayed.
If the unit is installed near a body of water, the installation parts are at risk of corroding. Appropriate anti-corrosion methods must be taken for
the unit and all installation parts.
Installing in an Area Exposed to Unconditioned Air
In some installation applications, areas (floors, walls) in some rooms will be exposed to unconditioned air (room will be above or next to an
unheated garage or storeroom). To countermeasure:
Verify that carpet is or will be installed (carpet could increase the temperature by three [3] degrees).
Add insulation between the floor joists.
Install radiant heat or another type of heating system to the floor.
Install a ventilation fan
with sufficient capacity
Heat or steam source
Include enough
distance
Indoor Unit
Figure 10: Installing Near a Heat or Steam Source.
Figure 11: Single Zone Art Cool Premier Wall Mount Indoor Unit Clear-
ance Requirements.
More than 8 inches
(200 mm)
More than
4 inches
(100 mm)
More than
4 inches
(100 mm)
At least 6-1/2 feet
(2 m) from the floor