Engineering and Specifications Manual

71
• Energy Saver Mode
• Auto Restart
• Digital Control Display
Dip Switch Setting for
Temperature Limiting
• Freeze Room Protection
• Front Desk Control
GoldFin ™ Anti-corrosion
Treatment for Condensor Coil
• High Energy Efciency
• Temperature Display on Unit
• Ultra-Quiet Operation
Dimension W x H x D (inch)
42 X 16 X 21
• LG Brand Compressors
• LG Brand BLDC Motors
Compatible with Most Energy
Management Systems
• Made by LG in LG Factories.
1-year full system limited warranty, parts and labor. Limited warranty on unit for years 2-5: parts only, exclusive of the refrigeration system.
Limited warranty on sealed refrigeration system: 5 years, parts and labor.
7,000-15,000 BTU/h Digital Control (265V)
Packaged Terminal
Air Conditioners
FEATURES:
*LG veried sound rating
**Adjustable by temperature limiting with DIP switches on the unit.
LP096HD3B (Heat Pump Model)
9,700 BTU/h Cooling & Heating
LP126HD3B (Heat Pump Model)
12,200 BTU/h Cooling & Heating
LP096CD3B (H/C Model)
9,700 BTU/h Cooling & Heating
LP126CD3B (H/C Model)
12,200 BTU/h Cooling & Heating
ULTRA
QUIET
LG PTAC
SYSTEMS
*Tested by Independent 3rd Party
(Cerami & Associates Inc., Jan. 2007)
* Sub Base assembly is mandatory for models rated 265V. (UL standard)
* Specification can be changed without notification
Model
Cooling
Capacity
(Btu/h)
EER
Heating
Capacity
(Btu/h)
COP
Net
Weight
(lbs)
Shipping
Weight
(lbs)
Sound
Pressure
IDU/ODU
(dBA)
Air
Circulation
H/L
(CFM)
Dehumidication
(pts/hr)
Power Supply
(V/Hz/Ph)
Electric
Heater
(kW)
MOP
(A)
MCA
(A)
Cooling
Rated
Amps
(A)
Heating
Rated
Amps
(A)
Cooling
Power
Input (W)
Heating
Power
Input (W)
LP096CD3B 9,700 12.8 106 120 46/61 270/225 2.6 265/60/1 3.7 20 17.9 3.0 755
LP126CD3B 12,200 11.9 106 120 50/63 420/353 3.0 265/60/1 3.7 20 17.9 4.0 1,025
265V HEATING & COOLING MODELS
Model
Cooling
Capacity
(Btu/h)
EER
Heating
Capacity
(Btu/h)
COP
Net
Weight
(lbs)
Shipping
Weight
(lbs)
Sound
Pressure
IDU/ODU
(dBA)
Air
Circulation
H/L
(CFM)
Dehumidication
(pts/hr)
Power Supply
(V/Hz/Ph)
Electric
Heater
(kW)
MOP
(A)
MCA
(A)
Cooling
Rated
Amps
(A)
Heating
Rated
Amps
(A)
Cooling
Power
Input (W)
Heating
Power
Input (W)
LP096HD3B 9,700 12.8 8,500 3.6 106 120 46/61 270/225 2.6 265/60/1 3.7 20 17.9 3.0 2.7 755 690
LP126HD3B 12,200 11.9 11,000 3.6 106 120 50/63 420/353 3.0 265/60/1 3.7 20 17.9 4.0 3.5 1,025 895
265V HEAT PUMP MODELS