LUU189HV Installation Manual

SELF-DIAGNOSIS FUNCTION
ENGLISH
19
SELF-DIAGNOSIS FUNCTION
Error Indicator (Outdoor)
Outdoor Error
Ex) Error 21 (DC Peack)
LUU368HV
LUU428HV
LUU488HV
LUU188HV
LUU189HV
LUU248HV
1 Time 1 Time 1 Time
2 Times2 Times2 Times
1 s
2 s 2 s
1 s 1 s
LED01G
(RED)
LED02G
(GREEN)
Error Code Description LED 1 (Red) LED 2 (Green) Indoor status
21 DC Peak(IPM Fault)
2times 1time
OFF
22 Max. CT(CT2)
2times 2times
OFF
23 DC Link Low Volt.
2times 3times
OFF
24 Pressure switch/Heater Sink.
2times 4times
OFF
26 DC Comp Position Error
2times 6times
OFF
27 PSC Fault Error
2times 7times
OFF
29 Comp Over Current
2times 9times
OFF
32 D-Pipe High(Inv.)
3times 2times
OFF
35 Low pressure Error
3times 5times
OFF
41 Inv. D-Pipe Th Error(Open/Short)
4times 1time
OFF
43 Pressure Sensor Error
4times 3times
OFF
44 Outdoor air Th Error(Open/Short)
4times 4times
OFF
45 Cond. Middle Pipe Th Error(Open/Short)
4times 5times
OFF
46 Suction Pipe Th Error(Open/Short)
4times 6times
OFF
48 Cond. Out-Pipe Th Error(Open/Short)
4times 8times
OFF
51 Capacity over
5times 1time
OFF
53
Communication Error(Indoor÷Outdoor)
5times 3times
OFF
54 Open and Reverse Phase Error
5times 4times
OFF
60 EEPROM Error(Outdoor)
6times
0 OFF
61 Cond. Middle Pipe High
6times 1time
OFF
62 Heatsink Error(High)
6times 2times
OFF
65 Heatsink Th Error(Open/Short)
6times 5times
OFF
67 BLDC motor fan lock(Outdoor)
6times 7times
OFF
73 PFC Fault Error(S/W)
7times 3times
OFF