LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 1 Dynamic Controller Owner’s Manual MODEL : LCC-K1000 Before installing and using the product, please read this owner's manual carefully and retain for future reference.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 3 IMPORTANT SAFETY INSTRUCTIONS CAUTION: PLEASE READ AND OBSERVE ALL WARNINGS AND INSTRUCTIONS IN THIS OWNER’S MANUAL. AND THOSE MARKED ON THE PRODUCT. RETAIN THIS BOOKLET FOR FUTURE REFERENCE. This product has been designed and manufactured to assure personal safety. Improper use can result in electric shock or fire hazard.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 4 Introduction Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 About Dynamic Controller . . . . . . . . . . . . . . . . .5 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Identification of the Controller . . . . . . . . . . . . .6-7 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Precautions . . . . . . . .
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 5 About Dynamic Controller This controller is the brand of Dome Camera Control Keyboard of LG in a surveillance system.You can operate this system very easily and conveniently because of design structure based on biotechnology and various functions for users. In addition, the controller can control using the whole functions of the LG Dome Camera such as zoom, focus and Pan/Tilt heads.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 6 Identification of the Controller 1 q; qa 2 qs qd 3 4 5 qf qg qh 6 7 qj 8 qk ql w; wa ws 6 9 wd wf
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 7 1 PTZ1 / PTZ2 Button Press to select a camera connected to the controller’s data ports. Press PTZ1 to control the camera connected to RS-485 1CH port. Press PTZ2 to control the camera connected to RS-485 2CH port. 2 Zone Buttons For details, see page 19. qd PTRN (Pattern) Buttons For details, see page 18. qf Alarm Buttons For details, see pages 16. qg Stop Button Stops the playback of recorded images or pattern playing back.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 8 Connections RS-485 Connection 5: TRX+ 6: TRX- Camera 1 Camera 2 RJ11 Cable (Supplied) DC 12V cable for Controller Precautions RS-485 Connection • The connections should be made by qualified service personnel or system installers in accordance with all local codes. • DC 12V can be used. Use the cable that is described below for RS-485 site communication. • Shielded, twisted pair cable • Low impedance • Wire gauge size is thicker than AWG #22 (0.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:50 PM Page 9 Setup Menu Setup Menu Overview The Setup menu has several submenus: System Setup, Preset Data Load, and Communication. All of these main menus are further divided into submenus.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 10 Key Functions on the Set Up Operation Start (Login) Set Up button: To display the main menu. Before starting operation, user authentication by the password is required. (Refer to page 21 for details on the setting of password.) SEL button: To execute or select modes and parameters. To enter a submenu for the selected item. Back button: To return to the previous menu. CLR (CLEAR) button: Removes a number on the menu.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 11 Communication Settings Protocol Setting This setting is required to establish a connection between the system units and system controller. This item lets you set a protocol for RS-485 communication. You can select the desired parameter from [LG MULTIX], [LG old], and [Reserved 1-6].
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 12 9. Preset Settings Preset position is the function to register camera monitoring positions (preset positions) associated with position numbers. By entering the position numbers, you can move cameras to the preset positions. Note: To activate this function, you need to register the preset positions of combination camera. To register preset positions 1. Press the Set Up button then select the [PRESET] icon.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 13 To tour the preset positions To group the preset positions You can tour all preset positions. You can create a group using preset positions that are registered already. A maximum of 9 group is available. 1. Press the Set Up button then select the [PRESET] icon. PRESET 000 PTZ 1. Press the Set Up button then select the [PRESET] icon. PRESET 000 PTZ 2. Press SEL. The sub menu will appear for [PRESET] setting. 3.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 14 To tour the group To clear the preset position You can tour the group that is registered already. You can delete a memorized preset position. 1. Press the Set Up button then select the [PRESET] icon. 1. Press the Set Up button then select the [PRESET] icon. PRESET 2. Press SEL. The sub menu will appear for [PRESET] setting. 3. Select [Group Tour] option then press SEL. The sub menu will appear.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 15 To clear all preset position To clear a group You can delete all memorized preset position. You can delete a memorized group. 1. Press the Set Up button then select the [PRESET] icon. 1. Press the Set Up button then select the [PRESET] icon. PRESET PRESET 000 PTZ 000 PTZ 2. Press SEL. The sub menu will appear for [PRESET] setting. 2. Press SEL. The sub menu will appear for [PRESET] setting. 3. Select [Clear All Preset] option then press SEL.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 16 To set Alarm Input To set Alarm Output You can set alarm input mode, alarm index, and duration time. Preset numbers 1 to 8 are linked to alarm inputs 1 to 8 respectively. If alarm input 1 comes in, the camera turns to preset position 1, and to other positions according to alarm input 2 to 8. (This operating description is based on the LG product.) You can set alarm output mode, alarm index, and duration time.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 17 Auto Pan Setup and Activation To activate auto pan You will set up and activate the auto pan function. The camera can pan among the points you will set. Note: Refer to the operating instructions of camera for details on the auto pan function. 1. Press the Set Up button then select the [AUTO PANNING] icon. AUTO PANNING 000 PTZ To set the points of auto pan 1. Press the Set Up button then select the [AUTO PANNING] icon. AUTO PANNING 000 PTZ 2.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 18 Pattern Setup and Activation You will perform the pattern setup and the pattern play. Note: The available patterns differ depending on camera. So please refer to camera’s manual. Note: Press CLR or Back button if you cancel the recording during recording a pattern. To record the pattern 1. Press the Set Up button then select the [PATTERN] icon. PATTERN 7. Perform desired camera operations by moving the joystick or pressing In/Out buttons.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 19 Privacy Setup To display or disappear privacy zone This setting is used for masking unwanted zones, hiding them from display on the monitor screen. Up to 8 zones can be registered. Submenus are provided for zone number selection and parameter setting. 1. Press the Set Up button then select the [PRIVACY ZONE] icon. PRIVACY ZONE 000 PTZ To register a new privacy zone 1. Press the Set Up button then select the [PRIVACY ZONE] icon.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 20 Configuration Settings PTZ Home Position In this menu, you can customize the settings provided. The home position is the camera’s basic position. The camera returns to this position after executing the [PTZ Home Position] option. Operation 1. Press the Set Up button then select the [CONFIGURATION] icon. CONFIGURATION 000 PTZ 2. Press SEL. The sub menu will appear for [CONFIGURATION] setting. 3. Use Arrow (M / m) buttons to select a desired option.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 21 Remote PTZ Reset You can reset the connected PTZ camera’s parameters to the factory default settings. PTZ 000 PTZ 000 Remote PTZ Reset Auto Key Lock Change Password [vV:bB] [ Reset PTZ Camera ] Are you sure? Auto Key Lock Setting The keys on the controller is locked when there is no operation for selected duration on the [Auto Key Lock] option. To release the Key Lock mode, you need to enter the password. NONE: Auto Key Lock function is disable.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 22 Camera Control Function Camera control functions are operable. It is necessary to set up the camera before using the camera control functions. For further information, refer to the Operating Instructions for the respective combination camera. You can also set it up from the Camera Setup menu during operating the system. Lens Control The following functions are available with cameras provided with controllable lens.
LCC-K1000_AABBLLG_ENG_75N 7/19/06 1:51 PM Page 23 Reference Specifications Communication Signal RS-485 Connector RJ11 Baud Rate 1,200 / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 / 57,600 / 112,500 bps Joy-Stick Type 3-Axis Control 256 Camera ID / Protocol Selection / Alarm Control Pan / Tilt / Zoom / Iris Focus 128 Positions Preset Touring 8 Positions Auto Panning 4 Pattern Setting Privacy Zone Masking (8 zones) Firmware Update RS-232C Total Key Number 44 Password 6 Digits Display 4 Gray
LCC-K1000_AABBLLG_ENG_75N P/NO : 3834RS0075N 7/19/06 1:51 PM Page 24