Brochure
-0@@0<BGG40@A>0@BAG40@A2=;>@4AA=@
)44>0645=@8<AB0::0B8=<;0B4@80:A
FLEX MULTI-SPLIT
-/"?
<4@6G)0D8<6
with LG inverter Technology
-8347=824=5<3==@+<8BA
Standard, Art Cool, Concealed Duct,
Cassette Types
4A86<:4F818:8BG
Outdoor units connect to several indoor unit styles
DUAL-ZONE
LMU186HV
TRI-ZONE
LMU246HV
QUAD-ZONE
LMU366HV
OUTDOOR UNITS H/P INVERTER
18,000-36,000 BTUs
"#+,
Dual-Zone
"#+,
Tri-Zone
"#+,
Quad-Zone
K45@=AB4828<6
K
(4AB0@B34:0G;8<CB4A
K )4:53806<=A8A
K)=5BAB0@B
KCB==>4@0B8=<@B858280:
8
<B4::864<24
KCB=@4AB0@B=>4@0B8=<
K"=E0;184<B=>4@0B8=<
K=:38<L<B8=@@=A8=<
Exterior Unit Includes:
KFB4@8=@C<8B
K)C558284<B@45@864@0<B5=@
270@68<6=@8<3==@2=8:A
&:40A4A44270@B14:=E5=@
02BC0::4<6B70;=C<B8<2:C343
*+()
DUAL-ZONE
LMU186HV
%CB3==@+<8BA&<D4@B4@
TRI-ZONE
LMU246HV
QUAD-ZONE
LMU366HV
%CB3==@#=34:&<D4@B4@ "#+, "#+, "#+,
Capacity * — BTU/h 18,000 Class 24,000 Class 36,000 Class
Power Input
(Min.~Rated~Max.) Cooling kW 0.52~1.25~2.05 0.72~1.56~3.27 0.72~3.75~3.92
Heating kW 0.77~1.63~2.18 0.72~3.22~3.5 0.72~3.70~4.10
Running Current Cooling A 2.3~5.8~9.5 3.0~7.2~15.2 3.0~17.4~18.2
Heating A 3.4~7.6~10.1 4.5~14.9~16.2 4.5~17.2~18.8
Power Supply — Ø / V / Hz 1/208~230/60 1/208~230/60 1/208~230/60
Power Supply Cable (Outdoor) — No. x AWG 3 x 14 3 x 12 3 x 12
Transmission Cable —
(Outdoor to Indoor unit )
No. x AWG 4 x 18 4 x 18 4 x 18
Dimensions (W x H x D) inch 34.3x25.8x12.6 34.3x31.8x12.6 34.3x31.8x12.6
Net Weight — lbs 115 143.3 143.3
Max. # of Connectable
Indoor Units
——234
Refrigerant Charge (at 24.6 ft.) oz 59.97 89.95 89.95
Type — R410A R410A R410A
Control — EEV EEV EEV
Sound Level (H/L) Sound Pressure dB(A)+3 51/45 52 52
Piping Connections Liquid inch 1/4 x 2EA 1/4 x 3EA 1/4 x 4EA
Gas inch 3/8 x 2EA 3/8 x 3EA 3/8 x 4EA
Piping length spec. Max. total piping ft. 164.0 246.1 246.1
Max. OD~ID piping ft. 82.0 82.0 82.0
Piping length(no add’l refrigerant) ft. 73.8 123.0 123.0
Max. Elevation Difference Outdoor Unit~Indoor Unit ft. 49.2 49.2 49.2
Indoor Unit~Indoor Unit ft. 24.6 24.6 24.6
Operation Range Cooling ˚F 14 ~114.8 14 ~114.8 14 ~114.8
(Outdoor) Heating ˚F 5~ 75.2 5~ 75.2 5~ 75.2
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 80ºF (26.7ºC ) DB/67ºF (19.4ºC) WB
- Outdoor Temperature 95ºF (35ºC) DB/75ºF (23.9ºC) WB
Heating: - Indoor Temperature 70ºF (21.1ºC) DB/60ºF (15.6ºC) WB
- Outdoor Temperature 47ºF (8.3ºC) DB/43ºF (6.1ºC) WB
Piping Length: - Interconnecting Piping Length 24.6 ft.(7.5m)
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose
of improvement.
4. For more capacity(*) information, refer to the combination tables.
5. The data mentioned in the above table are only for non-ducted type of indoor
unit.
K<AB0::0B8=<;0<C0:
*"